Jackson JFT Specification Sheet page 6

Jackson flight machine specification sheet

Advertisement

Steam
3" [72mm] Minimum
Floor Sink or Floor Drain
(Optional to drain at load
or unload end of the
machine.)
DIRECTION OF OPERATION
1
18" [457mm] I.D. Square
15'-5 1 2 " [4712mm]
14'-6" [4420mm]
13'-6" [4115mm]
12'-7 1 4 " [3840mm]
10'-8" [3250mm]
7'-8" [2335mm]
2'-5 3 8 " [745mm]
2'-4 3 8 " [719mm]
1
5
3' [914mm]
3' [913mm]
3' [915mm]
PREWASH
WASH
SECTION
SECTION
6
7'-8" [2335mm]
10'-8" [3250mm]
12'-7 1 4 " [3843mm]
13'-6" [4115mm]
14'-6" [4420mm]
15'-5 1 2 " [4712mm]
Condensate Exhaust Duct
Minimum 18" Square (Cross Section 324 Sq. In.)
Provided by HVAC Contractor
Exhaust Requirements
- 1200 CFM
Condensate duct to extended into duct pan.
Condensate duct pan mounted on top of
dishmachine electrical section.
Note:
The condensate removal system built into the dishmachine consists of a fan
that will remove 1200 CFM. A single condensate connection must be provided
by the installing contractor. This is an indirect connection that must be capable
of removing 1200 CFM from the area.
Visit us at www.jacksonmsc.com or call us at 1-888-800-5672
2
6
3' [914mm]
3' [914mm]
18'-6" [5639mm]
8
2
CONTROL
POWER RINSE
CABINET
SECTION
5
7
8
3
3"[76mm] Minimum
Floor Sink or Floor Drain
4
(Optional to drain at load or
unload end of the machine.)
1'-2 3 4 " [375mm]
3'-6" [1067mm]
4
3
7
Legend
1 - 1-1/2" NPT Machine Drain Connection
(Floor drain - optional to either end)
2 - Electrical Connection - See Table for Amp Draw
3 - 3/4" NPT Incoming Water Connection
4 - 1-1/2" NPT Steam Connection
5 - 3/4" NPT Wash Section Condensate Return
6 - 3/4" NPT Power Rinse Section Condensate Return
7 - 3/4" NPT Booster Heater Condensate Return
8 - Condensate Connection - See Detail