Advertisement

CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE.
CERTIFIED UNDER U.S. ENVIRONMENTAL PROTECTION AGENCY (E.P.A.) JULY 1990 40 C.F. R. PART 60 AND THE OREGON DEPARTMENT OF ENVIRON-
MENTAL QUALITY (D.E.Q.) PARTICULATE EMISSION STANDARDS BY E.E.M.C THESE STOVES HAVE BEEN TESTED AND LISTED BY INTERTEK TESTING
2300
PEDESTAL MODEL

SAFETY INFORMATION

WARNING
!
If the information in these instructions is not followed exactly, a
fi re or explosion may result causing property damage, personal
injury or death. Improper installation, adjustment, alteration,
service or maintenance can cause injury or property damage,
bodily injury or even death. Please read entire manual before
you install and use your appliance.
This appliance has not been tested with an unvented gas log
set. To reduce risk of fi re or injury, do not install an unvented
gas log set into the appliance.
- This appliance can be very hot when burning.
- Combustible materials such as fi rewood, wet clothing, etc. placed too
close can catch fi re.
- Children and pets must be kept from touching the appliance when it is hot.
- The chimney must be sound and free of cracks. Before installing this unit,
contact the local building or fi re authority and follow their guidelines.
- Operate only with the door tightly closed.
- Burn wood behind the log retainer directly on the fi rebricks.
- Do not use an elevated grate or otherwise raise the fi re.
- At least 14 square inches of outside air must be admitted to the room or
directly to the unit through a 4" diameter pipe.
- This appliance is designed to burn natural wood only. Higher effi ciencies
and lower emissions generally result when burning air dried seasoned
hardwoods, as compared to softwoods or to green or freshly cut
hardwoods.
- Do not start a fi re with chemicals or fl uids such as gasoline, engine oil,
etc.
- Do not burn treated wood, coal, charcoal, colored paper, cardboard,
solvents or garbage.
- Do not let the appliance become hot enough for any part to glow red.
- KEEP THE STOVE TOP TEMPERATURE BELOW 700°F (371°C). Attempts to
achieve heat output rates that exceed design specifi cations can result in
steel distortion and damage.
Phone (705)721-1212 • Fax (705)722-6031 • www.timberwolffi replaces.com • ask@timberwolffi replaces.com
$10.00
INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE.
OPERATING INSTRUCTIONS
SERVICES TO STANDARDS: CSA B366.2, ULC S627, UL 1482.
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 4Y8 Canada /
103 Miller Drive, Crittenden, Kentucky, USA, 41030
INSTALLATION AND
1.19
W415-0892 / 03.05.10
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 2300 and is the answer not in the manual?

Questions and answers

Summary of Contents for Timberwolf 2300

  • Page 1: Safety Information

    Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 4Y8 Canada / 103 Miller Drive, Crittenden, Kentucky, USA, 41030 Phone (705)721-1212 • Fax (705)722-6031 • www.timberwolffi replaces.com • ask@timberwolffi replaces.com 1.19 $10.00 W415-0892 / 03.05.10...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS INSTALLATION OVERVIEW INTRODUCTION DIMENSIONS SPECIFICATIONS GENERAL INSTRUCTIONS GENERAL INFORMATION RATING PLATE LOCATION PRE-INSTALLATION PREPARATION APPLIANCE PLACEMENT CLEARANCE TO COMBUSTIBLES FLOOR PROTECTION OUTSIDE AIR INSTALLATION CHIMNEY 4.1.1 CHIMNEY CONNECTION 4.1.2 ADDING SECTIONS 4.1.3 TYPICAL THROUGH THE CEILING 4.1.4 TYPICAL THROUGH THE WALL 4.1.5 TYPICAL EXISTING MASONRY...
  • Page 3: Installation Overview

    1.0 INSTALLATION OVERVIEW Blower, see Door, see “DOOR “OPTIONAL BLOWER REMOVAL / INSTALLATION” INSTALLATION” section. section. Handle, see “DOOR HANDLE INSTALLATION” section. Draft, see “DRAFT CONTROL” section. Outside air, see “OUTSIDE AIR” section. Ash, see “ASH REMOVAL PROCEDURES” section. W415-0892 / 03.05.10...
  • Page 4: Introduction

    2.0 INTRODUCTION WARNING • THIS APPLIANCE IS HOT WHEN OPERATED AND CAN CAUSE SEVERE BURNS IF CONTACTED. • Do not operate appliance before reading and understanding operating instructions. Failure to operate appliance according to operating instructions could cause fi re or injury. •...
  • Page 5: Dimensions

    7” 25 ³/ ” 12 ¾” 7” 31” 31 ¾” ” SPECIFICATIONS SPECIFICATIONS 2300 CHAMBER (D.W.H) 22 ½” x 18” x 12” CAPACITY 3.0 FT APPROX. AREA HEATED* 1000-3500 FT HEAT OUTPUT (HIGH BURN) ** 85,000 BTU DURATION LOW FIRE*...
  • Page 6: General Information

    • Before beginning your installation, consult with your local building code agency or fi re offi cials and insurance representative to ensure compliance. • Non-toxic smoke will be emitted during the paint curing process, to help dissipate the smoke open a window near the appliance.
  • Page 7: Rating Plate Location

    Expansion / contraction noises during heating up and cooling down cycles are normal and to be expected. After extended periods of non-operation such as following a vacation or a warm weather season, the appliance may emit a slight odour for a few hours. This is caused by dust particles on the fi rebox burning off. Open a window to suf- fi...
  • Page 8: Pre-Installation Preparation

    3.0 PRE-INSTALLATION PREPARATION APPLIANCE PLACEMENT Have an authorized dealer install the appliance. If you install the appliance yourself, have your dealer review your installation plans and/or installation. Draw out a detailed plan of the installation including dimensions and verify the dimensions with the require- ments listed in this manual.
  • Page 9: Outside Air

    OUTSIDE AIR WARNING IF ROOM AIR STARVATION OCCURS BECAUSE THE FRESH AIR INTAKE IS BLOCKED WITH ICE, LEAVES, ETC., OR BECAUSE THE APPLIANCE DOOR WAS LEFT OPEN, OR DUE TO A STRONG EXHAUST FAN OPERATING ETC., DANGEROUS FUMES AND SMOKE FROM THE OPERATING APPLI- ANCE COULD BE DRAWN INTO THE ROOM.
  • Page 10: Installation

    4.0 INSTALLATION WARNING WEAR GLOVES AND SAFETY GLASSES FOR PROTECTION. CAREFULLY FOLLOW THE INSTRUCTIONS FOR ASSEMBLY OF THE PIPE AND OTHER PARTS NEEDED TO INSTALL THE APPLIANCE. FAILURE TO DO SO MAY RESULT IN A FIRE, ESPECIALLY IF COMBUSTIBLES ARE TOO CLOSE TO THE APPLIANCE OR CHIMNEY AND AIR SPACES ARE BLOCKED, PREVENTING THE FREE MOVEMENT OF COOLING AIR.
  • Page 11: Chimney

    CHIMNEY WARNING NEVER INSTALL A SINGLE WALL SLIP SECTION OR SMOKE PIPE IN A CHASE STRUCTURE. THE HIGHER TEMPERATURE OF THIS SINGLE WALL PIPE MAY RADIATE SUFFICIENT HEAT TO COMBUSTIBLE CHASE MATERIALS TO CAUSE A FIRE. DO NOT CONNECT THIS APPLIANCE TO A CHIMNEY SYSTEM SERVING ANOTHER APPLIANCE. TO AVOID DANGER OF FIRE, ALL INSTRUCTIONS MUST BE STRICTLY FOLLOWED, INCLUDING THE PROVISION OF AIR SPACE CLEARANCE BETWEEN CHIMNEY SYSTEM AND ENCLOSURE.
  • Page 12: Chimney Connection

    4.1.1 CHIMNEY CONNECTION Your chimney connector and chimney must have the same diameter as the appliance’s exhaust outlet. The appliance pipe must be made of aluminized or cold roll steel with a minimum 24 gauge thickness. It is strictly forbidden to use galvanized steel. A 6”...
  • Page 13: Adding Sections

    4.1.2 ADDING SECTIONS Add chimney sections, according to the manufacturers installation instructions. The chimney must extend at least, 3 feet above its point of contact with the roof and at least 2 feet higher than any wall, roof or building within 10 feet horizontally.
  • Page 14: Typical Through The Ceiling

    4.1.3 TYPICAL THROUGH THE CEILING Move the stove into position with the fl ue centered, midpoint between two joists to prevent having to cut them. Use a plumb bob to line up the center. Cut and frame an opening in the ceiling to provide a 2” clearance between the outside of the chimney and any combustible material.
  • Page 15: Typical Through The Wall

    4.1.4 TYPICAL THROUGH THE WALL If possible, design the installation so that the connector does not pass through a combustible wall. If during your installation you must pass through a combustible wall, check with your building inspector before you be- gin.
  • Page 16: Typical Existing Masonry

    4.1.5 TYPICAL EXISTING MASONRY You can also install your appliance using your existing masonry chimney. To do so, follow the guidelines below. You may want to use a factory- built thimble, or construct your own brick thimble. If you are using a masonry chimney, it is important that it be built in compliance with the specifi...
  • Page 17: Finishing

    5.0 FINISHING DOOR REMOVAL / INSTALLATION PINS 5.1.1 Pivot the door open and lift up to clear the bushings. Do not pivot the door any further than necessary. 5.1.2 Carefully set the door aside and pull the pins out from the door bushings. Repeat in reverse order to install the door.
  • Page 18: Bricks And Baffle Installation

    BRICKS AND BAFFLE INSTALLATION WARNING OPERATION OF THE APPLIANCE WITHOUT THE BAFFLES CAN RESULT IN EXCESSIVE TEMPERA- TURES THAT COULD DAMAGE THE APPLIANCE, CHIMNEY AND THE SURROUNDING ENCLOSURE. With stove and chimney installation completed, move the bricks into place as illustrated. 5.3.1 Install three courses of brick on both sides of the unit.
  • Page 19 With appliance and chimney installation Brick completed, move the bricks into place for your 2300 Retainers appliance as illustrated. Install the bottom bricks, working from the back of the appliance forward.
  • Page 20: Optional Kit Installations

    6.0 OPTIONAL KIT INSTALLATIONS OPTIONAL BLOWER INSTALLATION WARNING RISK OF FIRE AND ELECTRICAL SHOCK. TURN OFF THE ELECTRICAL POWER BEFORE SERVICING THIS APPLIANCE. USE ONLY WOLF STEEL APPROVED OPTIONAL ACCESSORIES AND REPLACEMENT PARTS WITH THIS APPLIANCE. USING NON-LISTED ACCESSORIES (BLOWERS, DOORS, LOUVRES, TRIMS, ETC.) COULD RESULT IN A SAFETY HAZARD AND WILL VOID THE WARRANTY AND CERTIFICATION.
  • Page 21: Operation

    BURNING YOUR APPLIANCE WITH THE DOORS OPEN OR AJAR CREATES A FIRE HAZARD THAT MAY RESULT IN A HOUSE AND OR CHIMNEY FIRE. Your Timberwolf EPA listed product is a Hi-tech appliance, designed with the most advanced technology. The appli- ance is extremely airtight.
  • Page 22: Air Control

    You can now add larger pieces of wood and operate the appliance normally. Once the appliance is entirely hot, it will burn very effi ciently with little smoke from the chimney. There will be a bed of orange coals in the fi rebox and secondary fl...
  • Page 23: Fuel

    FUEL WARNING DO NOT STORE FUEL WITHIN THE CLEARANCE TO COMBUSTIBLES, OR IN THE SPACE REQUIRED FOR RE-FUELING AND ASH REMOVAL. BURNING WET, UNSEASONED WOOD CAN CAUSE EXCESSIVE CREOSOTE ACCUMULATION. WHEN IGNITED IT CAN CAUSE A CHIMNEY FIRE THAT MAY RESULT IN A SERIOUS HOUSE FIRE. When loading the appliance, ensure that the two upper fi...
  • Page 24: Maintenance

    8.0 MAINTENANCE WARNING TURN OFF THE POWER BEFORE SERVICING THE APPLIANCE. APPLIANCE MAY BE HOT, DO NOT SERVICE UNTIL APPLIANCE HAS COOLED. DO NOT USE ABRASIVE CLEANERS. Check your chimney and chimney connector for creosote and soot buildup weekly until a safe frequency for cleaning is established.
  • Page 25: Creosote Formation And Removal

    CREOSOTE FORMATION AND REMOVAL When wood is burned slowly, it produces tar and other organic vapours which combine with expelled moisture to form creosote. These vapours condense in the relatively cooler chimney fl ue of a slow burning fi re and when ignited, make an extremely hot fi...
  • Page 26: Glass Replacement

    GLASS REPLACEMENT WARNING DO NOT USE SUBSTITUTE MATERIALS. GLASS MAY BE HOT, DO NOT TOUCH GLASS UNTIL COOLED. CARE MUST BE TAKEN WHEN REMOVING AND DISPOSING OF ANY BROKEN DOOR GLASS OR DAMAGED COMPONENTS. BE SURE TO VACUUM UP ANY BROKEN GLASS FROM INSIDE THE APPLIANCE BEFORE OPERATION.
  • Page 27: Care Of Glass

    CARE OF GLASS If the glass is not kept clean permanent discolouration and / or WARNING blemishes may result. Normally a hot fi re will clean the glass. The most common reasons for dirty glass include: not using HOT GLASS WILL suffi...
  • Page 28: Replacements

    9.0 REPLACEMENTS Contact your dealer or the factory for questions concerning prices and policies on replacement parts. Normally all parts can be ordered through your Authorized dealer / distributor. FOR WARRANTY REPLACEMENT PARTS, A PHOTOCOPY OF THE ORIGINAL INVOICE WILL BE REQUIRED TO HONOUR THE CLAIM.
  • Page 29 W415-0892 / 03.05.10...
  • Page 30: Trouble Shooting

    10.0 TROUBLE SHOOTING WARNING TURN OFF THE ELECTRICAL POWER BEFORE SERVICING THE APPLIANCE. APPLIANCE MAY BE HOT, DO NOT SERVICE UNTIL APPLIANCE HAS COOLED. DO NOT USE ABRASIVE CLEANERS. WHEN CHECKING CONNECTIONS, INSTALLING JUMPER WIRES (FOR TEST PURPOSES ONLY) OR REPLACING COMPONENTS, UNPLUG HEATER FROM THE RECEPTACLE TO PREVENT ELECTRICAL SHOCK OR DAMPAGE TO THE COMPONENT.
  • Page 31: Warranty

    After the fi rst year, with respect to the TIMBERWOLF’S President’s Limited Warranty, Wolf Steel may, at its discretion, fully discharge all obligations with respect to this warranty by refunding to the original warranted purchaser the wholesale price of any warranted but defective parts.
  • Page 32: Service History

    12.0 SERVICE HISTORY 43.1 W415-0892 / 03.05.10...
  • Page 33: Notes

    13.0 NOTES 44.1 W415-0892 / 03.05.10...
  • Page 34 44.1 W415-0892 / 03.05.10...
  • Page 35 44.1 W415-0892 / 03.05.10...

Table of Contents