Testing MAP or BP/MAP Sensors with
Frequency Output
To use the Frequency function to check barometric
pressure/ manifold absolute pressure (BP/MAP) sensors:
1.
Insert the test leads in the input terminals as shown in
Figure 10.
2.
Set the rotary switch to
3.
Connect the test lead clips to the circuit according to
the manufacturer's wiring diagrams.
Press G once to select frequency. Hz appears on
4.
the display. Press C repeatedly to step to the 6 V
range. "6" should appear at the right side of the display.
Use E to change trigger slope.
5.
With the ignition KEY ON but the ENGINE OFF
(KOEO), pump the vacuum up.
6.
Watch the frequency change on the display. Compare
the frequency at various vacuum readings with the
specifications in the vehicle's service manual. At 0
inches of mercury, the frequency should match
specification for your altitude.