Download Print this page
Bosch DS9360 Installation Manual

Bosch DS9360 Installation Manual

Tritech ceiling mount pir/microwave detector

Advertisement

Quick Links

3. If adequate range can not be reached, increase the Microwave Range
Adjust slightly. Continue walk testing (waiting 1 minute after removing/
replacing the cover) and adjusting the range until the farthest edge of
desired coverage has been accurately placed.
4. Walk test the unit from all directions to determine all the detection pat-
tern boundaries.
MIN
Figure 6.2: Adjusting microwave range
NOTICE!
Do not adjust the microwave range higher than required. Doing so may
cause the detector to catch movement outside of the intended cover-
age pattern.
8 Supervision Features
The supervision features function as follows:
PIR/Microwave: The complete circuit operation of these subsystems is
checked approximately every 6 hours. If the PIR or microwave subsys-
tem fails, the red LED will fl ash 4 times per cycle and the unit should
be replaced.
Default: The detector will default to PIR technology protection if the
microwave subsystem fails.
9 Other Information
9.1 Anti-Vandal Screws for EN50131 Applications
After the cover has been installed and twisted into place, the entire as-
sembly can be secured together using the supplied anti-vandal screws. The
anit-vandal screws are required for EN50131 applications. Refer to the Top
View of Enclosure in Figure 2.2 for the location of the screw holes.
9.2 Maintenance
At least once a year, the range and coverage should be verifi ed. To en-
sure continual daily operation, the end user should be instructed to walk
through the far end of the coverage pattern. This ensures an alarm output
prior to arming the system.
Reading Bosch Security Systems, Inc. Product Date Codes
For Product Date Code information, refer to the Bosch Security Systems, Inc.
Web site at: http://www.boschsecurity.com/datecodes/.
© 2012 Bosch Security Systems, Inc. 130 Perinton Parkway Fairport, NY 14450
Microwave
Adjustment
MAX
TriTech Ceiling Mount
PIR/Microwave Detector
DS9360
en Installation Guide

Advertisement

loading
Need help?

Need help?

Do you have a question about the DS9360 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Bosch DS9360

  • Page 1 Reading Bosch Security Systems, Inc. Product Date Codes For Product Date Code information, refer to the Bosch Security Systems, Inc. Web site at: http://www.boschsecurity.com/datecodes/. © 2012 Bosch Security Systems, Inc. 130 Perinton Parkway Fairport, NY 14450...
  • Page 2 7.1 LED On/Off Pins Changes or modifi cations not expressly approved EN 50131-2-4 Grade 2 by Bosch Security Systems, Inc. can void the user’s EN 50130-5 Environmental Class II The ON position allows operation of the tri-color LED. If LED indication is authority to operate the equipment.
  • Page 3 3. Route wiring as necessary to the rear of the base and through the cen- If the detector experiences a Microwave or PIR self-test failure, it is in need ter hole. Refer to Figure 2.2. of replacement. 6 © 2012 Bosch Security Systems, Inc. F.01U.263.664 | 01 | 05.2012 | 3...
  • Page 4 Mounting to removable ceiling tiles is not recommended unless a • The DS9360 comes with a choice of two optical modules. Refer to Sec- sandwich is made of the base, ceiling tile, and a back plate behind the tion 5.1 to determine the best module for on ceiling height.