3. If adequate range can not be reached, increase the Microwave Range
Adjust slightly. Continue walk testing (waiting 1 minute after removing/
replacing the cover) and adjusting the range until the farthest edge of
desired coverage has been accurately placed.
4. Walk test the unit from all directions to determine all the detection pat-
tern boundaries.
MIN
Figure 6.2: Adjusting microwave range
NOTICE!
Do not adjust the microwave range higher than required. Doing so may
cause the detector to catch movement outside of the intended cover-
age pattern.
8 Supervision Features
The supervision features function as follows:
•
PIR/Microwave: The complete circuit operation of these subsystems is
checked approximately every 6 hours. If the PIR or microwave subsys-
tem fails, the red LED will fl ash 4 times per cycle and the unit should
be replaced.
•
Default: The detector will default to PIR technology protection if the
microwave subsystem fails.
9 Other Information
9.1 Anti-Vandal Screws for EN50131 Applications
After the cover has been installed and twisted into place, the entire as-
sembly can be secured together using the supplied anti-vandal screws. The
anit-vandal screws are required for EN50131 applications. Refer to the Top
View of Enclosure in Figure 2.2 for the location of the screw holes.
9.2 Maintenance
At least once a year, the range and coverage should be verifi ed. To en-
sure continual daily operation, the end user should be instructed to walk
through the far end of the coverage pattern. This ensures an alarm output
prior to arming the system.
Reading Bosch Security Systems, Inc. Product Date Codes
For Product Date Code information, refer to the Bosch Security Systems, Inc.
Web site at: http://www.boschsecurity.com/datecodes/.
© 2012 Bosch Security Systems, Inc. 130 Perinton Parkway Fairport, NY 14450
Microwave
Adjustment
MAX
TriTech Ceiling Mount
PIR/Microwave Detector
DS9360
en Installation Guide
Need help?
Do you have a question about the DS9360 and is the answer not in the manual?
Questions and answers