Operation Panel - Noritz NR83-DVC Installation Manual

Tankless gas water heater
Hide thumbs Also See for NR83-DVC:
Table of Contents

Advertisement

Operation Panel

* The water heater has been factory set to allow a maximum temperature setting of 120 °F (50 °C).
To access higher temperature settings through the remote controller, follow the below steps.
<When setting the maximum temperature to 125-140 °F (55-60 °C)>
1. Turn the water heater off by pressing the ON/OFF button on the remote controller.
2. Press and hold the FLOW METER ALARM SET button until a sound is heard (2 sec.) and 120 °F (50
°C) appears on the display.
3. Set the upper limit of the hot-water supply temperature to 125 °F, 130 °F (55 °C), 135 °F or 140 °F (60
°C) using the UP and DOWN setting buttons.
4. To put the water heater back into operation, press the ON/OFF button on the remote controller.
To keep the water heater off, let the unit sit for 30 sec. to return to the original display.
• The NR83-DVC can be programmed so that it will default to one of three temperatures if the remote
controller is removed (140, 130, 120 °F (60, 55, 50 °C). To change the default temperature, adjust the
dip switches as described below. The default temperature is 120 °F (50 °C).
1. Disconnect electrical power to the water heater.
2. Remove the front cover of the water heater (4 screws).
3. Disconnect the remote controller. Adjust the dip switches as illustrated below.
4. Replace the front cover of the water heater (4 screws).
5. Reconnect electrical power to the water.
• When changing the temperature, make sure to confi rm with the customer that the temperature of
the hot water will be very high and that there is a risk of scalding.
• Water temperatures above 120 °F (50 °C) can cause severe burns or death from scalding.
23
* Do not change any other dipswitches.
* High temperature.
1
2
Standard
130 F (55 C)
140 F (60 C)
ON=
OFF=
WARNING

Hide quick links: