3-6. OUTDOOR FAN CONTROL

Fan speed is switched according to the number of operating indoor unit and the compressor frequency.
MXZ-2B20NA
<Relation between compressor frequency and fan speed>
MXZ-2B20NA
NOTE: When the indoor coil thermistor is 134.6 ˚F (57°C) or more on HEAT operation, fan speed is fixed to Low speed.
Or, the indoor coil thermistor is 113 ˚F (45°C) or less on HEAT operation, fan speed is back to normal.
MXZ-2B20NA-
MXZ-3B MXZ-4B
1
COOL
Fan speed changes so that the condensing temperature stays within the target range.
Fan speed
MXZ-2B20NA-
1
2
3
4
5
6
7
8
9
10
11
12
13
14
HEAT
Fan speed is switched according to the compressor frequency.
Fan speed
MXZ-2B20NA-
Up
Down
Compressor frequency (Hz)
Down
Up
30
40
Revolution per minutes (rpm)
MXZ-3B
1
MXZ-4B
100
100
150
150
200
200
250
250
300
300
350
350
400
400
450
450
500
500
550
550
600
600
650
650
700
700
750
750
Compressor speed (Hz)
MXZ-3B
1
MXZ-4B
30
50
23
40
Fan speed
Down
High
Low
Min.
Compressor frequency
Frequency (Hz) Target condensing temperature (°F/°C)
~24
25~34
35~44
45~54
55~64
65~
Fan speed
Down
High
Low
Min.
Compressor frequency
32
Up
Max.
87.8/31-95.0/35
91.4/33-98.6/37
95.0/35-102.2/39
98.6/37-105.8/41
98.6/37-105.8/41
98.6/37-105.8/41
Up
Max.