3. Outdoor power P.C. board
MXZ-3D54VA
MXZ-3D68VA
CN5
Primary current
detection
(Connect to the
noise filter)
(
Signal reception
(From electronic
control P.C.
board)
5V DC pulse
wave
CN3
Fin temperature
thermistor RT64
CN2
Connect to the controller board
(+)1-5(–): Signal transmission
(To electronic control P.C. board)
5V DC pulse wave
(+)2-5(–): Zero cross signal
3-4
: Not used
(+)6-5(–): 15V
(+)7-5(–): 15V
OBH626B
MXZ-4D72VA
94
Fin temperature thermistor (RT64)
200
180
160
140
120
100
80
60
40
20
0
0
10 20 30 40 50 60 70 80
Temperature (°C)
(Red)
(+)
1
325-370V DC
Output
3
(–)
(White)
Connect to the earth
Connect to the
compressor
Voltage among
phases: 5V to 180V