Mitsubishi Electric MXZ-2D33VA-E1 Service Manual page 77

Split-type air conditioners
Hide thumbs Also See for MXZ-2D33VA-E1:
Table of Contents

Advertisement

11-5. TROUBLE CRITERION OF MAIN PARTS
MXZ-2D33VA MXZ-2D40VA MXZ-2D53VA MXZ-2D53VAH
MXZ-3D54VA MXZ-3D68VA MXZ-4D72VA MXZ-4D83VA MXZ-5D102VA
Part name
Defrost thermistor (RT61)
Fin temperature thermistor (RT64)
Ambient temperature thermistor
(RT65)
Outdoor heat exchanger
temperature
thermistor (RT68)
Discharge temperature thermistor
(RT62)
Compressor
W
RED
V
U
WHT
BLK
Outdoor fan motor
WHT
RED BLK
2
3
1
W
V
U
MXZ-2D33VA/40VA/53VA
MXZ-2D53VAH
MXZ-4D83VA/5D102VA
Outdoor fan motor
MXZ-3D54VA/3D68VA/4D72VA
R.V. coil
Linear expansion valve
WHT
LEV
RED
ORN
YLW
BLU
High pressure switch (HPS)
MXZ-3D68VA/4D72VA
MXZ-4D83VA/5D102VA
Defrost heater
MXZ-2D53VAH
OBH626B
Measure the resistance with a tester.
Refer to 11-7. "TEST POINT DIAGRAM AND VOLTAGE" 1. "Inverter P.C. board", 2.
"Outdoor control P.C. board " or 3. "Outdoor power P.C. board" for the chart of thermis-
tor.
Measure the resistance with a tester.
Before measurement, hold the thermistor with your hands to warm it up.
Refer to 11-7. "TEST POINT DIAGRAM AND VOLTAGE" 1. "Inverter P.C. board", 2.
"Outdoor control P.C. board ", for the chart of thermistor.
Measure the resistance between terminals with a tester.
(Winding temperature : -10 °C ~ 40 °C)
Normal (Each phase)
MXZ-2D53VA
MXZ-2D33VA
MXZ-2D53VAH
MXZ-2D40VA
MXZ-3D54VA
1.49
~ 1.84
0.86
Measure the resistance between lead wires with a tester.
(Part temperature : -10 °C ~ 40 °C)
Normal (Each phase)
MXZ-2D
12
~ 16
Refer to 11-6.
.
Measure the resistance with a tester. (Part temperature : -10 °C ~ 40 °C)
Normal
MXZ-2D33VA
MXZ-2D40VA
MXZ-3D54VA
MXZ-2D53VA
MXZ-3D68VA
MXZ-2D53VAH
MXZ-4D72VA
MXZ-4D83VA
MXZ-5D102VA
1.2 k ~ 1.56 k
1.26 k ~ 1.62 k
Measure the resistance with a tester. (Part temperature : -10 °C ~ 40 °C)
Color of lead wire
WHT - RED
RED - ORN
YLW - RED
RED - BLU
Pressure
HPS
Measure the resistance with a tester. (Part temperature : -10 °C ~ 40 °C)
Normal
349
~ 428
77
Check method and criterion
MXZ-3D68VA
MXZ-4D72VA
~ 1.06
0.63
~ 0.78
MXZ-4D83VA
MXZ-5D102VA
13.4
~ 16.4
Normal
37.4
~ 53.9
3.7
0.3 MPa
4.8
0.2 MPa
MXZ-4D83VA
MXZ-5D102VA
1.29
~ 1.49
Normal
Close