Table of Contents

Advertisement

Available languages

Available languages

Quick Links

IMPORTANT INSTRUCTIONS -
ESQZ Series
READ AND SAVE THESE INSTRUCTIONS
READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED.
PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH
INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE!
When using electrical appliances, basic precautions should always be followed to
reduce the risk of fire, electric shock and injury to person, including the following:
WARNING:
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK AND
INJURY TO PERSON, OBSERVE THE FOLLOWING:
a) Use this unit only in the manner intended by the manufacturer.If you have
questions, contact the manufacturer.
b) Before servicing or cleaning the unit, switch power off at service panel and
lock the service disconnecting means to prevent power from being switched on
accidentally. When the service disconnecting means cannot be locked, securely
fasten a prominent warning device, such as a tag, to the service panel.
WARNING:
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK AND
INJURY TO PERSON, OBSERVE THE FOLLOWING:
a) Installation work and electrical wiring must be done by qualified person(s) in
accordance with all applicable codes and standards, including fire-related
construction.
b) Sufficient air is needed for proper combustion and exhausting of gases through
the flue (chimney) of fuel burning equipment to prevent back drafting. Follow
the heating equipment manufacturer's guideline and safety standards such
as those published by the National Fire Protection Association (NFPA) and the
American Society for Heating, Refrigeration, and Air Conditioning Engineers
(ASHRAE), and the local code authorities.
c) When cutting or drilling into wall or ceiling, do not damage electrical wiring and
other hidden utilities.
CAUTION:
FOR GENERAL VENTILATING USE ONLY. DO NOT USE TO
EXHAUST HAZARDOUS OR EXPLOSIVE MATERIALS AND VAPORS.
CAUTION:
TO REDUCE THE RISK OF FIRE AND TO PROPERLY EXHAUST
AIR, BE SURE TO DUCT AIR OUTSIDE - DO NOT VENT EXHAUST AIR INTO
SPACES WITHIN WALLS OR CEILINGS OR INTO ATTICS, CRAWL SPACES, OR
GARAGES.
d) Ducted fans must always be vented to the outdoors.
e) This unit must be grounded.
f)
To avoid motor bearing damage and noisy and/or unbalanced impellers, keep
drywall spray, construction dust, etc. off power unit.
g) Read all instructions before installing or using range hood.
6728010 Rev A 10-13
OPERATING MANUAL
RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.

GENERAL SAFETY INFORMATION

SAVE THESE INSTRUCTIONS
WARNING:
USE THIS FAN WITH ANY SOLID-STATE SPEED CONTROL DEVICE.
WARNING: TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
a) Never leave surface units unattended at high settings. Boilovers cause
smoking and greasy spillovers that may ignite. Heat oils slowly on low or
medium settings.
b) Always turn hood ON when cooking at high heat or when flambéing food
(ie. Crepes Suzette, Cherries Jubilee, Peppercorn Beef Flambé).
c) Clean ventilating fans frequently. Grease should not be allowed to
accumulate on fan filter.
d) Use proper pan size. Always use cookware appropriate for the size of the
surface element.
WARNING:
EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING:
a) SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray, then
turn off burner. BE CAREFUL TO PREVENT BURNS. If the flames do not go out
immediately, EVACUATE AND CALL THE FIRE DEPARTMENT.
b) NEVER PICK UP A FLAMING PAN - You may be burned.
c) DO NOT USE WATER, including wet dishcloths or towels -
a violent steam explosion will result.
d) Use an extinguisher ONLY if:
I.
II.
III.
IV.
WARNING:
DUCTWORK.
www.airkinglimited.com
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, DO NOT
TO REDUCE THE RISK OF INJURY TO PERSONS IN THE
You know you have a Class ABC extinguisher, and you already know
how to operate it.
The fire is small and contained in the area where it started.
The fire department is being called.
You can fight the fire with your back to an exit.
TO REDUCE THE RISK OF FIRE, USE ONLY METAL
Range Hood
1 of 12

Advertisement

Table of Contents
loading

Summary of Contents for Air King ESQZ Series

  • Page 1: General Safety Information

    IMPORTANT INSTRUCTIONS - OPERATING MANUAL ESQZ Series Range Hood READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE! RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
  • Page 2: Installation Instructions

    SECTION 3 INSTALLATION INSTRUCTIONS Prepare the Hood for Installation CAUTION: MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL BEFORE Choose the type of ducting you will require. To ensure the best air and sound performance, STARTING INSTALLATION. it is recommended that the length of ducting and the number of elbows be kept to a minimum, the radius of each elbow be as large as possible for the installation, and that SECTION 1 hard ducting be used.
  • Page 3 NOTE: DO NOT disconnect any wiring that has already been crimped with a wire connector Hood from the factory. Body Install the wire compartment cover and tighten screw. Make sure all wiring is securely E-22A/RCD7 contained within the wire compartment. Damper SECTION 6 Ducting...
  • Page 4: Troubleshooting Guide

    Reverse the instructions in the “Finishing the Installation” section of the instructions to remove filter. If the grease filter becomes damaged, replace with Air King Model GF-08S Grease Filter. Charcoal Odor Filter - If you have installed an optional combination grease/charcoal filter, it cannot be washed and must be discarded and replaced when it becomes noticeably dirty, has stopped filtering the odors, or at least once per year.
  • Page 5: Limited Warranty

    WHAT AIR KING WILL DO: During the warranty period, Air King will, at its sole option, repair or replace any part or parts that prove to be defective or replace the whole product with the same or comparable model.
  • Page 6 REPLACEMENT PARTS DIAGRAM Qty. Description Replacement Part # Motor 5S1146001 Motor Pad 5S1146002 Undercarriage (White) 5S1146003 Undercarriage (Black) 5S1146063 Impeller 5S1146012 Filter GF-08 5S1146004 Filter CF-08 5S1146005 Wire Compartment Cover 5S4199005 Lamp Holder 5S1146006 GU24 26 watt Lamp 5S9999010 Night Light Lamp Holder 5S1146007 Light Lens 5S4109005...
  • Page 7: Instructions Générales De Sécurité

    INSTRUCCIONES IMPORTANTES – MANUAL DE OPERACIÓN Séries ESQZ Hotte de cuisinière LIRE ET CONSERVER CES INSTRUCTIONS LIRE SOIGNEUSEMENT AVANT DE TENTER D’ASSEMBLER, INSTALLER, OPÉRER OU DE RÉPARER LE PRODUIT DÉCRIT. PROTÉGEZ VOUS-MÊME ET LES AUTRES EN OBSERVANT TOUTE L’INFORMATION DE SÉCURITÉ. FAILLIR À SE CONFORM- ER AUX INSTRUCTIONS PEUT RÉSULTER EN BLESSURE PERSONNELLE GRAVE ET/OU EN DOMMAGE À...
  • Page 8: Installation De La Hotte

    SECTION 3 INSTRUCTIONS D’INSTALLATION Préparez la hotte pour l’installation MISE EN GARDE : ASSUREZ-VOUS QUE L’ALIMENTATION ÉLECTRIQUE Choisir le type de conduits qui sera requis. Pour garantir la meilleure qualité d’air et EST COUPÉE À PARTIR DU PANNEAU DE DISTRIBUTION AVANT DE COMMENCER performance acoustique, il est recommandé...
  • Page 9 REMARQUE : NE PAS déconnecter quelque fil qui ait déjà été serti avec un connecteur de fil à l’usine. Hotte Placez le couvercle du compartiment de fils et serrez la vis. Assurez-vous que tous les E-22A/RCD7 fils sont placés de manière sécuritaire à l’intérieur du compartiment. Onglets Clapet SECTION 7...
  • Page 10: Guide De Dépannage

    être lavés et doivent être jetés lorsqu’ils deviennent notablement sales, qu’ils aient cessé de filtrer les odeurs, ou au moins une fois par année. Remplacer avec un Filtre Combiné à Graisse / Odeur Modèle CF-08S de Air King. Guide de dépannage...
  • Page 11: Garantie Limitée

    Cette garantie ne couvre pas les coûts d'expédition pour le retour des produits à Air King pour la réparation ou le remplacement. Air King payera les frais d'expédition de retour de Air King après les réparations ou le remplacement de garantie.
  • Page 12 DIAGRAMME DES PIÈCES DE REMPLACEMENT # de pièce Qte. Description de remplacement Moteur 5S1146001 Plaquette de moteur 5S1146002 Châssis (Blanc) 5S1146003 Châssis (Noir) 5S1146063 Hélice 5S1146012 Filtre (GF-08) 5S1146004 Filtre (CF-08) 5S1146005 Couvercle de compartiment à câblage 5S4199005 Support à lampe 5S1146006 Lampe GU24 de 26 watts 5S9999010...

Table of Contents