SW-A6 No. 2 End buzzer
Setting this bit to 0 will disable the end buzzer (including the error buzzer/
on-hook buzzer).
SW-A6 No. 3 Disconnect the line when DIS is received in RX mode
Bit1 = 0 : When DIS signal is received during RX mode, disconnect the
line immediately.
Bit1 = 1 : When DIS signal is received during RX mode, wait for the next
signal.
SW-A6 No. 4 Equalizer freeze control (MODEM)
This switch is used to perform reception operation by fixing the equal-
izer control of modem for the line which is always in unfavorable state
and picture cannot be received.
* Usually, the control is executed according to the state of line where the
equalizer setting is changed always.
SW-A6 No.5 Equalizer freeze 7200BPS only
Setting which specifies SW-A6 No. 4 control only in condition of 7200BPS
modem speed.
SW-A6 No. 6 CNG transmission in manual TX mode
When set to "1", fax transmit the CNG signal in case of manual
transmissiom mode (User press the START key after waiting for the fax
answering signal from handset or speaker).
SW-A6 No. 7 Initial compression scheme for sharp fax in TX mode
When set to "0", if the other fax is Sharp model, fax transmit the docu-
ment by H2 mode.
When set to "1", even if the other fax is Sharp model, fax transmit the
document by MR mode.
SW-A6 No. 8 Modem speed automatic down when RX level is under
-40dBm
When set to "1", if fax signal level is under -40dBm during reception,
machine selects the slower modem speed automatically.
It is effective when noises occur on the received document due to the
long distance communications.
SW-A7 No. 1, No. 2 EOL (End Of Line) detect timer
Used to make a choice of whether to use the 5 or 13 or 20 or 25 seconds
timer for detection of EOL.
This is effective to override communication failures with some facsimile
models that have longer EOL detection.
SW-A7 No. 3 ~ No. 8 Reserved
Set to "0".
SW-B1 No. 1 Reserved
Set to "0".
SW-B1 No. 2 Auto dial fax transmission by REDIAL key
When set to "1", if original documents are set to the feeder and you
press REDIAL key, machine will dial and transmit the ducuments auto-
matically.
When set to "0", operator needs to press the START key after FAX re-
ception tone is heard.
SW-B1 No. 3 Reserved
Set to "0".
SW-B1 No. 4 ~ No. 8 Recall interval
(0~15.5min setting by 0.5min step)
Choice is made for a redial interval for speed and rapid dial calls.
Use a binary number to program this with 0.5min steps. If set to 0 acci-
dentally, 0.5min will be assumed.
SW-B2 No. 1 ~ No.4 Recall times (0~15times setting)
Choice is made as to how many redials there should be.
SW-B2 No. 5 Dial tone detection (Before auto dial)
Used to set YES/NO of dial tone detection in auto dialing.
SW-B2 No. 6 Reserved
Set to "0".
SW-B2 No. 7 Busy tone detection (After auto dial)
Used to set YES/NO of busy tone detection after auto dialing.
SW-B2 No. 8 Busy tone detection pulse number (After auto dial)
Used for detection of busy tone in 2 or 4 pulses.
SW-B3 No. 1, No. 2 Waiting time after dialing
This is waiting time for the opponent's signals after dialing.
45 / 55 / 90 / 140 seconds settings are available.
SW-B2 No. 3 PBX connection
Used to select according to the connected line: PBX (Private Branch
Exchange).
SW-B3 No. 4 Reserved
Set to "0".
SW-B3 No. 5, No. 6 PBX recall function (R key select)
Used to set the operation mode of PBX recall when the R key is pressed.
Setting is made according to the type of PBX.
No. 5=1, No. 6=1: Time break recall (=Flash) is performed.
SW-B3 No. 7, No. 8 PBX select
Used to select the operation mode of PBX recall in auto dialing.
No. 7=1, No. 8=1: Time break recall (=Flash) is performed before dialing.
No. 7=0, No. 8=0: The PBX ID digit is automatically added when dialing
to external line. PBX ID is up to 3 digits and entered in
Option settings mode.
SW-B4 No. 1 Dialing pause (sec/pause)
Pauses can be inserted between telephone numbers of direct dial con-
nection. Selection of 4 sec or 2 sec pause is available.
SW-B4 No. 2 Dial mode
When using the pulse dial, set to 0. When using the tone dial, set to 1.
SW-B4 No. 3 Pulse → Tone change function by
When setting to 1, the mode is changed by pressing the
pulse dial mode to the tone dial mode.
SW-B4 No. 4 Dial pulse make/break ratio (%)
When using the 33% make ratio pulse dial, set to 0.
When using the 40% make ratio pulse dial, set to 1.
SW-B4 No. 5, No. 6 Auto dial mode Delay timer of before line con-
nect
Delay time between the dial key input and line connection under the
auto dial mode.
RAPID A
No.5=0 No.6=0 : 0sec
No.5=0 No.6=1 : 1.5sec
No.5=1 No.6=0 : 3.0sec
No.5=1 No.6=1 : 4.5sec
SW-B4 No. 7, No. 8 Reserved
Set to "0".
2 – 14
key
key from the
CML RELAY ON
DIALLING