NATURAL GAS
Manual Pressure
Regulator Pressure Setting: 4.0" w.c.
Gas Inlet Pressure:
Model Number
Control
PH24NM
Manual
PH24NV
Millivolt
PH18NM
Manual
PH18NV
Millivolt
PROPANE/LPG
Note: An external regulator is required to reduce supply pressure to a maximum of 13" w.c.
Manual Pressure
Regulator Pressure Setting: 10" w.c.
Gas Inlet Pressure:
Model Number
Control
PH24PM
Manual
PH24PV
Millivolt
PH18PM
Manual
PH18PV
Millivolt
IGNITION CONTROLS
Piezo ignitor allows ignition of the pilot without the use of matches or batteries.
Manual control has three (3) positions:
OFF -
All gas to the gas logs is shut off at the valve.
IGN -
Valve position to light/maintain a standing pilot.
HI/LOW -
Variable position corresponding to desired flame height (heat input)
Millivolt control has four (4) positions:
OFF -
All gas to the gas logs is shut off at the valve.
IGN -
Valve position to light/maintain a standing pilot.
ON -
Valve position to turn ON/OFF log set with remote switch/thermostat.
HI/LOW -
Variable position to control flame height (heat output).
PILOT
The gas log heater is fitted with a specially designed safety pilot light (ODS assembly) which senses the amount of oxygen
available in the room and shuts the gas log heater off if the oxygen level begins to drop below a satisfactory level. The pilot
can only be relit when adequate fresh air is available.
THERMAL GENERATOR
The millivolt gas log pilot is fitted with a millivolt generator to provide power for remote activation.
6

SPECIFICATIONS

AND
Max. 10 1/2" w. c.
Min. 5" w.c.
Gas Rate
Max BTU/Hr
36,000
36,000
30,000
30,000
Maximum 13" w.c.
Minimum 11" w.c.
Gas Rate
Max BTU/Hr
36,000
36,000
30,000
30,000
Millivolt Pressure
Regulator Pressure Setting: 3.5" w.c.
Pilot Regulator:
Gas Inlet Pressure:
Min BTU/Hr
19,000
24,000
18,000
26,000
Millivolt Pressure
Regulator Pressure Setting: 10" w.c.
Gas Inlet Pressure:
Min BTU/Hr
25,000
29,000
22,500
24,500
3.5" w.c.
Max. 10 1/2" w. c.
Min. 5" w.c.
Maximum 13" w.c.
Minimum 11" w.c.