Connecting The Gas - Prime Heat PH18 Installation And Operating Instructions Manual

Unvented gas log heater or vented decorative appliance, natural or propane gas control type: manual or millivolt
Table of Contents

Advertisement

NOTICE: A qualifi ed gas appliance installer must connect the heater to the gas supply. Consult all local
codes.
Use new black iron or steel pipe. Internally tinned copper or copper tubing can be used
per National Fuel Code, section 2.6.3, providing gas meets hydrogen sulfi de limits, and
where permitted by local codes. Gas piping system must be sized to provide minimum
inlet pressure (Listed on Data Plate) at the maximum fl ow rate (BTU/Hr). Undue pressure
loss will occur if the pipe is too small.
A manual shutoff valve must be installed upstream of the appliance. Union tee and
plugged 1/8" NPT pressure tapping point should be installed upstream of the appliance.
See Figure 13.
To Heater
Valve
IMPORTANT: Hold heater valve firmly with a wrench to prevent movement when connecting to inlet pipe.
CHECK GAS TYPE: The gas supply must be the same as stated on the heater's rating
plate. If the gas supply is different, DO NOT INSTALL THE HEATER. Contact your dealer
for the correct model.
Always use an external regulator for all propane/LPG heaters and high pressure one to two-pound systems only, to
reduce the supply tank pressure to a maximum of 13" w.c. This is in addition to the internal regulator in the heater valve.
65D2035
Pipe Coupling
Stainless
Flexible Tube
Manual Shutoff
Valve
Figure 13 - Gas Connection
Pipe
Locations that the Pressure
Tapping Point May Be

CONNECTING THE GAS

Gas Supply
Inlet
17