Proper Air Hose And Tool Use; Pressure Control Related Devices; Compressor - Tool Requirements; Attaching/Disconnecting Air Hose And Tools - NorthStar 25654 Owner's Manual

Electric portable air compressor (115v/15a or 230v/7.5a, single phase/20 gallon, 2 hp)
Table of Contents

Advertisement

Start-Up Procedures
CAUTION: Break-in period
Before initial use, open the drain valve and run the
compressor without air tools attached and through open
air line for 30 minutes to break-in pump parts.
1. Verify that the pressure switch is in the OFF position.
(Figure 5)
Off
2. Turn regulator counter clockwise to close.
3. Verify that the pressure gauge reads zero.
4. Open the drain valve so that air flow is permitted.
5. Turn the pressure switch to the ON position.
6. Adjust regulator to desired pressure.
7. Allow pressure in receiver tank to build.
Note: This electric model is equipped with a pressure
switch that automatically turns the motor off when the
tank pressure reaches its preset level. Once air
pressure in the tank drops to a preset low level, the
pressure switch automatically turns the motor back on.
WARNING: Overheating
This compressor is equipped with "auto shut off".
However, failure to allow adequate cooling ventilation or
a restriction in the intake airflow may cause the
machine to overheat.
WARNING: Inflatables/Low PSI tire
Never use compressor to inflate small low-pressure
objects, i.e., balloons/inflatables, small or low volume
PSI tires. It is easy to over-pressurize them, causing
them to rupture. Identify the inflation capacity of an
object prior to filling it with air. Use a gauge to check the
pressure regularly when inflating anything.

Proper Air Hose and Tool Use

Pressure Control Related Devices

Never remove, adjust, bypass, change, modify or make
substitutions for safety/relief valves, pressure switches
or other pressure control related devices. Pressurizing
beyond the limits of the compressor could result in an
explosion.
On
Figure 5
WARNING: Overpressurization hazard
NEVER over-pressurize the receiver tank or air tools
beyond nameplate capacity. Exceeding the pressure
rating could cause them to explode or fly apart.

Compressor - Tool Requirements

 Compressor and attachments must be sized properly
for pressure and air volume.
 Consider the maximum pressure requirements and
air volume requirements of each. (The volume rating
of your compressor is listed in the "Specifications"
section.)
CAUTION: Tool overpressure hazard
Do not operate this unit with any tool rated less than the
maximum operating pressure of the unit (135 PSI)
unless a properly sized regulator limiting pressure is
used before the tool.

Attaching/Disconnecting Air Hose and Tools

CAUTION: High pressure stream hazard
High-pressure air stream can pierce skin and underlying
tissues, leading to serious injury and possible
amputation. Such an injection injury can result in blood
poisoning and/or severe tissue damage. High-pressure
air stream can also cause flying debris and possible
surface damage.
On a fixed line distribution system the flexible hosing
and tools would typically be connected at a terminating
point. In some cases where a fixed system does not
exist, the flexible hosing can be attached to the quick
connect fitting on the main compressor outlet or after the
user installed regulator.
CAUTION: Air tools hazard
Do not attach air tools to open end of the hose until
start-up is completed and the unit checks out OK.
Quick Connect Procedure:
Keep finger off tool or activation switch until ready
to use.
Pull quick connect collar back (Figure 6a).
Push hose or attachment firmly against stop.
Let go of collar (Figure 6b).
Pull and rotate slightly (hose or attachment) to
assure a tight connection.
WARNING: Projectile hazard
Air tool or attachment can become a projectile and
cause serious personal injury or damage if not securely
attached to the air hose.
10

Advertisement

Table of Contents
loading

This manual is also suitable for:

25653

Table of Contents