Compressor Runs Too Much Or 100; Noisy - Electrolux FROST- FREE Service Manual

Table of Contents

Advertisement

Complaint.

Compressor Runs Too Much or 100%.

Noisy.

Clause-Remedy
1. Erratic control thermostat, or setting too cold -
replace are reset to normal position.
2. Freezer exposed to unusual heat - relocate freezer.
3. Abnormally high room temperature - advised
customer.
4. Low pumping capacity compressor - replaced
compressor.
5. Lid gasket not ceiling - adjust or replace necessary
parts.
6. System undercharged - check for leaks.
8. Interior light stays on - check lid switch.
9. Non-condensables in system - replaced filter drier,
evacuate, and recharge.
10. Capillary tube kinked or partially restricted - replace
heat exchanger.
11. Filter drier, partially restricted - replace filter drier.
12. Excessive service load - advise customer.
13. Restricted airflow over condenser - ensure condenser
has unobstructed airflow.
1. Tubing vibrates - adjust tubing.
2. Internal compressor noise - replaced compressor.
3. Compressor vibrating on cabinet frame - just
compressor.
4. Loose parts - check shelving, kick plate, and
defrost drain pan.
5. Compressor operating at high head pressure due to
restricted airflow around freezer - ensure freezer is
installed properly.
29