Mitsubishi Electric MSZ-G09SV-E1 Service Manual page 38

Split-type, heat pump air conditioners wireless type
Hide thumbs Also See for MSZ-G09SV-E1:
Table of Contents

Advertisement

(2) Time chart
Air conditioner ON
Positioning
Standard
opening
degree
13 min.
ON
(3) Control data
(a) Reference value of target discharge temperature
(COOL/HEAT :)
A
-
MSZ-G09SV
E1
58/49
-
MSZ-G09SV
E2
-
MSZ-G12SV
E1
57/48
-
MSZ-G12SV
E2
In COOL mode, the two indoor coil thermistor (one main and one sub) sense temperature ununiformity (super heat)
at the heat exchanger, And when temperature difference have developed, the indoor coil thermistors adjust LEV
opening to get approximate 10 degrees lower temperature than the target temperature in the table above, thus
diminishing super heat.
(b) Reference value of LEV standard degree opening
(COOL/ HEAT pulse)
01
-
MSZ-G09SV
E1
150/70
-
MSZ-G09SV
E2
-
MSZ-G12SV
E1
160/90 190/120 200/140 220/160 240/180 255/200
-
MSZ-G12SV
E2
Opening degree is
corrected according
to discharge
temperature.
OFF Time
B
C
D
63/58
69/66
74/71
60/57
67/66
75/71
02
03
04
170/90
180/110
190/140
Air conditioner OFF
(thermostat off)
Commanded
to open
Time
06
05
04
E
F
03
02
74/76
74/78
01
78/76
78/78
05
06
200/150
200/160
38
C
B
A(target discharge temperature)
30
50
70
90
The operational frequency of the compressor
F
E
D
110
130
(Hz)

Hide quick links: