Current Compatible Communicating Products
Air Conditioning units - - 180B, 187B, 186B
Heat Pumps - - 286B, 289B, 285B
Gas Furnace - - 355AAV, 315AAV, 315JAV, 355CAV
Fan Coils - - FE
Small Packaged Products - - 577D, 707D, 607D, 677D
Physical Characteristics
Dimensions: See drawing
Appearance: Plastic, white color, textured
Electrical Characteristics/Communication
Input Volts/Amps 24VAC
Each device in the Evolution System has a four- -pin
connector labeled ABCD. It is recommended that the
following color code be used when wiring each device:
A — Green = Data A
B — Yellow = Data B
C — White = 24VAC (Com)
D — Red = 24VAC (Hot)
Environmental Requirements:
Operating Temperature/Relative Humidity:
User interface and all sensors: 32_F to 104_F / 0_C to 40_C,
95% rh non- -condensing
Storage Temperature/Relative Humidity:
User interface: - - 40_F to 134_F / - -40_C to 56.7_C, 95% rh
non- -condensing
Evolution Control (4--- Wire User Interface w/ multiple functionality)
Evolution Network Interface Module (NIM)
*
Required for ventilator control
Required for Hybrid Heat applications with non- -communicating heat pumps
Required for use with 2- -stage (non- -communicating) AC or HP (598A / 698A)
Evolution Remote Room Sensor
Evolution Large Decorative Backplate
10 Pack Replacement --- Green Indoor Unit Plug (ABCD Connector)
Evolution System Access Module (Remote Access Kit, Wired, CAT5)
Evolution System Access Module (Remote Access Kit, Wireless WiFi)
Outdoor Sensor
*
Not required, but may be used to remote sense indoor room temperature.
PRODUCT DATA INFORMATION
Equipment
DESCRIPTION
Optional Accessories
DESCRIPTION
Feature Specifications:
Temperature set point range: 40_F to 90_F / 4.4_C to 32.2_C
Separate heat and cool setpoints
Programming days: 7 day
Programming periods:
2- -Day, Sleep
4- -Wake, Day, Eve, Sleep
Non- -Programmable
Auto changeover (may be disabled)
Programmable fan (installer selectable)
Humidity Sensor Offsets
Auto Changeover Timer (installer adjustable)
Smart Recovery (in heating and cooling)
Hold function
Copy functions: Copy period, day and zone
Permanent memory
Humidity display and control
Temperature sensor offsets (indoor and outdoor)
TrueSenset Dirty Filter Detection
Wiring Requirements:
Power supply: Dedicated 24VAC, 40 va, 60 Hz, via indoor
equipment ABCD Connector. Isolated transformer, field
supplied.
Wiring material: Standard thermostat wire 18 to 24 gauge.