Setup
OPTION 3 - Pre-Comfort Recovery
1. Press SET again to select pre-comfort recovery. (rE:0 will flash)
2. Press ▲ or ▼ to adjust setting. (See pre-comfort recovery supplementary information on page 13.)
rE:0 = pre-comfort recovery feature disabled.
rE:1 = pre-comfort recovery feature enabled.
3. Press SET to proceed to OPTION 4 or wait for 15 seconds to confirm and exit Option Settings.
OPTION 4 - ºC or ºF (Celsius or Fahrenheit scale) Display
1. Press SET to select Celsius or Fahrenheit scale. (Current temperature will flash.)
2. Press ▲ or ▼ to toggle between ºC or ºF temperature scales.
3. Press SET or wait for 15 seconds to confirm and exit Option Settings.
Note: A change of the temperature display mode will result in the reset of all programs.
(i.e. All programs set by user will be deleted.)
Heat Cycle Rate supplementary information
Cycle rate determines the heating on/off time cycles and the level of proportional power required
to operate the heater.
(To have the heater operate at full power all the time, select Cr:0 to disable heat cycling.)
The cycle rate is based on the type of heating system and the power load required to operate the device.
The higher the load (size of baseboard or radiant heater), the greater the heat generated.