Trim Installation - MHSC B36RA8 Installation, Operation And Maintenance Manual

Woodburning fireplaces
Table of Contents

Advertisement

B36LA8 & B36RA8 Woodburning Fireplaces

TRIM INSTALLATION

The face of your fireplace may be left exposed or trimmed with any noncombustible material such as brick,
stone or marble. Figure 30. If a noncombustible trim is installed, be sure it is fastened snugly to the face of
the fireplace. A crack between the material and the face of the fireplace could pose a fire hazard and impair
the proper operation of the fireplace. Blocking the fireplace with framing and attaching the base to the sup-
porting floor will further reduce the possibility of such a crack developing.
CAUTION: Do not allow any trim materials to extend closer than 3/8" to the vertical edges of the firebox
opening if you plan to equip the fireplace with glass doors.
Wall ties should be fastened to the face of the fireplace with sheet metal screws and placed in the mortar
joints of masonry trim.
Combustible material must not be installed below the top spacers of the fireplace or overlap the sides of
the fireplace face. Seal the face of the fireplace to the surrounding wall with noncombustible caulk or trim
materials to prevent cold air leakage around the fireplace.
CAUTION: No trim should block or restrict in any way the flow of air into the air inlets in the face of the
fireplace. Figures 30 and 31
Be sure to provide the required floor protection as described in a preceding section of this manual. Page
13, Figure 10
Combustible mantels and trim must be installed in accordance with the National Fire Protection Association
- ANSI NFPA 211 Standard - Section 7-2.3.3.
Glass Door Installation
This fireplace has been tested and listed for use with Model MGD36B or MGD36PB glass doors. For instal-
lation of the Model MGD36B or MGD36PB glass doors, refer to the instructions provided with the doors.
Installation of Noncombustible Facing Materials to the Front Face of the Fireplace
Figure 30
Do Not Install Combustible
Framing or Trim Below Top
Edge of Fireplace
Top of Fireplace
Opening
* For B Models, facing
materials can be brought
to the top of the fireplace
opening
CAUTION: Do not allow any trim materials to extend closer than 3/8 inch to the vertical edges of the
firebox opening if glass doors are to be installed.
NOTE: On B36LA8 or B36RA8 Models, noncombustible facing materials may be installed to the
top of the fireplace opening. This facing material must be secured and sealed to the face of the
fireplace. Failure to properly secure and seal noncombustible facing material to the fireplace can
cause a possible fire hazard and will void the warranty.
26
Noncombustible Facing
Material
Fireplace Face
CAUTION: Do not cover or
restrict vent areas with any trim
materials.
M1021
Use Only Noncombustible Materials
Below Top of Spacers
Steel Lintel
(Optional)
TRIM INSTALLATION
WARNING: The space between the face
of the fireplace and the noncombustible
facing material must be sealed. Failure to
properly seal this crack can cause a pos-
sible fire hazard and will void the MHSC
warranty.
87D0176

Advertisement

Table of Contents
loading

This manual is also suitable for:

B36la8

Table of Contents