Hitachi RAK-65NH5 Instruction Manual
Hitachi RAK-65NH5 Instruction Manual

Hitachi RAK-65NH5 Instruction Manual

Split type air conditioner
Hide thumbs Also See for RAK-65NH5:

Advertisement

Quick Links

SPLIT TYPE AIR CONDITIONER
Instruction manual
To obtain the best performance and ensure years of trouble
free use, please read this instruction manual completely.
Bedlenungsanleitung
Bitte lesen Sie diese Bedienungsanleitung aufmerksam
durch, um durch richtige Bedienung jahrelangen und
störungsfreien Betrieb zu gewährleisten.
Mode d'emploi
Des performances optimales et un fonctionnement à long
terme seront assurés en appliquant les présentes
instructions après avoir entièrement lu ce mode d'emploi.
Manuale di istruzioni
Per garantire la migliore prestazione e la più lunga
durataleggere attentamente e al completo le seguanti
istruzioni.
(EN1) RAK-65NH5

INDOOR UNIT

MODEL
RAK-65NH5
INDOOR UNIT
RAK-65NH5
Page 1~24
Suite 25~48
Page 49~72
Pag. 73~96
– 1 –
1
Manual de instrucciones
Para obtener el mejor funcionamiento y asegurar años de
uso libre de problemas, lea cuidadosamente este manual
de instrucciones.
Manual de instruções
A fim de obter um bom funcionamento e de garantir uma
utilização sem falhas durante muitos anos, é favor ler este
manual de instruções completamente.
O‰ËÁ›Â˜ XÂÈÚÈÛÌÔ‡
°È· ÙËÓ Î·Ï‡ÙÂÚË ‰˘Ó·Ù‹ ·fi‰ÔÛË Î·È ÙËÓ Ì·ÎÚÔ¯ÚfiÓÈ·
Î·È ¯ˆÚ›˜ ÚԂϋ̷ٷ ¯Ú‹ÛË Ù˘ Û˘Û΢‹˜ ·˘Ù‹˜,
·Ú·Î·Ïԇ̠‰È·‚¿ÛÙ ϋڈ˜ ÙȘ Ô‰ËÁ›Â˜ ¯ÂÈÚÈÛÌÔ‡ Ù˘.
Инструкция по эксплуатации
Для
обеспечения
наилууших
характеристик и многолетней безотказной работы
оборудования необходимо полностыо оэнакомиться с
данной Инструкцией по эксплуатации.
5/1/06, 4:02 PM
Página 97~120
Página 121~144
™ÂÏ›‰· 145~168
стр. 169~192
эксплуатационных

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RAK-65NH5 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Hitachi RAK-65NH5

  • Page 1: Indoor Unit

    Per garantire la migliore prestazione e la più lunga Для обеспечения наилууших эксплуатационных durataleggere attentamente e al completo le seguanti характеристик и многолетней безотказной работы istruzioni. оборудования необходимо полностыо оэнакомиться с данной Инструкцией по эксплуатации. – 1 – (EN1) RAK-65NH5 5/1/06, 4:02 PM...
  • Page 2: Safety Precaution

    Before cleaning, be sure to stop the operation and turn the breaker OFF. Do not use any conductor as fuse wire, this could cause fatal accident. During thunder storm, disconnect and turn off the circuit breaker. – 2 – (EN1) RAK-65NH5 5/1/06, 4:02 PM...
  • Page 3 This appliance is not intended for use by young children or infirm persons unless they have been adequately supervised by a responsible person to ensure that they can use the appliance safely. Young children should be supervised to ensure that they do not play with the appliance. – 3 – (EN1) RAK-65NH5 5/1/06, 4:02 PM...
  • Page 4: Names And Functions Of Each Part

    Remote controller Send out operation signal to the indoor unit. So as to operate the whole unit. (Refer page 6) MODEL NAME AND DIMENSIONS MODEL WIDTH (mm) HEIGHT (mm) DEPTH (mm) RAK-65NH5 1030 – 4 – (EN1) RAK-65NH5 5/1/06, 4:02 PM...
  • Page 5 TEMPORARY SWITCH TEMPORARY SWITCH TEMPORARY SWITCH Use this switch to start and stop when the remote controller does not work. By pressing the temporary switch, the operation is done in automatic mode. – 5 – (EN1) RAK-65NH5 5/1/06, 4:02 PM...
  • Page 6: Names And Functions Of Remote Control Unit

    This is to protect the device and does not indicate a failure. TIMER SELECTOR If you press the FUNCTION selector button during operation, the ON TIMER OFF TIMER device may stop for about 3 minutes for protection. AUTO SWING – 6 – (EN1) RAK-65NH5 5/1/06, 4:03 PM...
  • Page 7: Automatic Operation

    The display does not indicate the preset temperature in the AUTO mode. If you change the setting, the indoor unit will produce a beep. Press the (FAN SPEED) button, AUTO and LOW is available. – 7 – (EN1) RAK-65NH5 5/1/06, 4:03 PM...
  • Page 8: Heating Operation

    Press the button again to stop operation. STOP I As the settings are stored in memory in the remote controller, you only have to press the (START/STOP) button next time. – 8 – (EN1) RAK-65NH5 5/1/06, 4:03 PM...
  • Page 9: Dehumidifying Operation

    The function will stop (the indoor unit will stop emitting air) as soon as the room temperature becomes lower than the setting temperature. – 9 – (EN1) RAK-65NH5 5/1/06, 4:03 PM...
  • Page 10: Cooling Operation

    I As the settings are stored in memory in the remote controller, you only have to press the (START/STOP) button next time. – 10 – (EN1) RAK-65NH5 5/1/06, 4:03 PM...
  • Page 11: Fan Operation

    For the cooling operation After room temperature reaches the preset temperature, the cooling operation, which changes the fan speed and room temperature to obtain optimum conditions for natural healthful cooling will be performed. – 11 – (EN1) RAK-65NH5 5/1/06, 4:03 PM...
  • Page 12: How To Set The Timer

    Point the signal window of the remote controller toward the indoor unit, and press the (CANCEL) button. (RESERVED) sign goes out with a beep and the (TIMER) lamp turns off on the indoor unit. NOTE You can set only one of the OFF-timer, ON-timer and ON/OFF-timer. – 12 – (EN1) RAK-65NH5 5/1/06, 4:03 PM...
  • Page 13 As the time settings are stored in memory in the remote controller, you only have to press (RESERVE) button in order to use the same settings next time. – 13 – (EN1) RAK-65NH5 5/1/06, 4:03 PM...
  • Page 14: How To Set The Sleep Timer

    You can not set other timer during sleep timer operation. After sleep timer time is up and when press sleep button again, the sleep timer will be set as last setting. Sleep timer effective only once. – 14 – (EN1) RAK-65NH5 5/1/06, 4:03 PM...
  • Page 15: Adjusting The Air Deflector

    Adjustment of the conditioned air to the left and right. Hold the vertical air deflector as shown in the figure and adjust the conditioned air to the left and right. – 15 – (EN2) RAK-65NH5 5/1/06, 4:03 PM...
  • Page 16: How To Exchange The Batteries In The Remote Controller

    1. Do not use new and old batteries, or different kinds of batteries together. 2. Take out the batteries when you do not use the remote controller for 2 or 3 months. – 16 – (EN2) RAK-65NH5 5/1/06, 4:03 PM...
  • Page 17: Suitable Room Temperature

    Please pay attention to the room temperature electric energy, please clean the filter every 2 and air flow direction when operating the unit weeks. for baby, children and old folks who have difficulty in movement. – 17 – (EN2) RAK-65NH5 5/1/06, 4:03 PM...
  • Page 18 Caution Inverter-type fluorescent To avoid noise interference, please place the indoor lamp. unit and its remote controller at least 1m away from To prevent electrical products. interference, place at least 1m away. – 18 – (EN2) RAK-65NH5 5/1/06, 4:03 PM...
  • Page 19: Attaching The Air Cleansing And Deodorizing Filters

    Type number for this air cleansing filter is <SPX-CFH5>. Please use this number for ordering when you want to renew it. Do not operate the air conditioner without filter. Dust may enter the air conditioner and fault may occur. – 19 – (EN2) RAK-65NH5 5/1/06, 4:03 PM...
  • Page 20: Maintenance

    When washing it, shake off moisture completely and dry it in the shade; do not expose it directly to the sun. The filter may shrink. Do not use detergent on the air cleansing and deodorizing filter as some detergent may deteriorate the filter electrostatic performance. – 20 – (EN2) RAK-65NH5 5/1/06, 4:03 PM...
  • Page 21 Do not splash or direct water to the body of the unit when cleaning it as this may cause short circuit. Never use hot water (above 40°C), benzine, gasoline, acid, thinner or a brush, because they will damage the plastic surface and the coating. – 21 – (EN2) RAK-65NH5 5/1/06, 4:03 PM...
  • Page 22: Regular Inspection

    Is the mounting frame seriously affected by rust and is the outdoor unit tilted or unstable? Is the plug of power line firmly plugged into the socket? (Please ensure no loose contact between them). Confirm – 22 – (EN2) RAK-65NH5 5/1/06, 4:03 PM...
  • Page 23 The recommended maximum and minimum operating temperatures of the hot and cold sides should be as below: Cooling Heating Minimum Maximum Minimum Maximum Dry bulb °C Indoor Wet bulb °C Dry bulb °C Outdoor Wet bulb °C – 23 – (EN2) RAK-65NH5 5/1/06, 4:03 PM...
  • Page 24 ........................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................ – 24 – (EN2) RAK-65NH5 5/1/06, 4:03 PM...

Table of Contents