EZ-LINK SYSTEM DUAL INSTALLATION

The EZ-Link™ system is designed to electronically control two continuous flow gas water heaters and have
them operate as one. One or both water heaters may be in operation, depending upon the hot water
demand. The second water heater will only operate when the hot water demand exceeds the capacity of the
first water heater to supply.
The EZ-Link system is suitable for installation with 884 and 886 series 024 model continuous flow gas water
heaters. The Ez-Link Kit PN 290141 is required for the installation.
cable clamps
x 2
Notes:
Only two continuous flow gas water heaters can be installed with an Ez-Link system.
The Ez-Link system will vary the start up sequence of the two water heaters.
The two continuous flow water heaters must be of the same model. The performance of two different
model water heaters manifolded together cannot be guaranteed.
A temperature controller is required to be installed with the EZ-Link system.
If the preset outlet temperature of the water heater is set at greater than 60°C, the maximum outlet
temperature of the water heater will be limited by the maximum temperature setting of the temperature
controller.
Warning: Two continuous flow water heaters manifolded together with an Ez-Link system installed
cannot be used as an in-series gas booster system to a solar water heater installation. Temperature
controllers must not be fitted to a water heater if it is installed as an in-series gas booster with a solar water
heater, because water at a temperature much higher than the controller setting can be delivered.
Ez-Link cable x 1
screws x 2
Ez-Link Kit – PN 290141
warning label x 1
(121109)
49
AGA label x 1
(121901)