Download Print this page
Invacare 2001 Maintenance Instructions
Invacare 2001 Maintenance Instructions

Invacare 2001 Maintenance Instructions

Heavy duty cleaning procedure for invacare continuing care group tubs

Advertisement

Quick Links

Heavy Duty Cleaning Procedure

Maintenance Instructions
For Invacare Continuing Care Group Tubs
DO NOT use this product or any available optional equipment without first completely reading and understanding these
instructions and any additional instructional material such as owner's manuals, service manuals or instruction sheets supplied
with this product or optional equipment. If you are unable to understand the warnings, cautions or instructions, contact a
healthcare professional, dealer or technical personnel before attempting to use this equipment - otherwise, injury or damage may
occur.
The disinfectant dispensing system has been factory tested and calibrated for use with Invacare disinfectant. The use of any disinfectant
with a dilution ratio (½ oz. per gallon) or viscosity level different than that of Invacare disinfectant will result in an improper mixture of
disinfectant and water. This may cause your system to be improperly disinfected - or in some instances, not disinfected at all. If using
any disinfectant with a dilution ratio or viscosity level different than that of Invacare disinfectant or if switching from one type of
disinfectant to another type, the disinfectant flowmeter must be calibrated before performing this procedure. Refer to the tub owner's
manual or to the calibration instruction sheet, part number 1154272, for the calibration procedure.
ALWAYS wear rubber gloves, an apron and face shield protection during disinfecting, cleaning and rinsing procedures. In case of
eye or skin contact, follow procedures on disinfectant container.
NEVER use abrasive cleaners like scouring powder or liquid cleaners containing pumice stone. The use of these types of cleaners
will make the gel-coat finish of your tub scratched and dull. NEVER use cleaners containing iodine, bromine, Betadine
methylene blue. The use of these types of cleaners will cause the tub to stain. Never use cleaners containing bleach. Use of these
types of cleaners will dry out the rubber seals and gaskets and the tub will not function properly.
Before starting the whirlpool pump, the water level must be completely above the whirlpool jets. Otherwise damage to the
motor/pump will result.
Heavy Duty Cleaning Procedure
In addition to disinfecting your tub after every use, you will need to perform this procedure 
approximately once every 80‐150 baths.
1.
Clean the entire surface of the tub to remove visible tissue residue and fluid.
2.
Rinse the inside surface of the tub with the shower/massage wand on the spray setting.
3.
Rotate the water temperature valve to adjust the water temperature to approximately 
o
105
 F.
NOTE: This will maximize the cleaning solutionʹs ability to clean and disinfect the system.
4.
Close the drain.
5.
Make sure the whirlpool jets are open.
6.
Fill the tub one inch above the highest whirlpool jets.
7.
Add the Invacare Heavy Duty Cleaner to the water in the tub. Refer to the chart for the 
proper amount.
8.
Spray pre‐mixed Invacare Heavy Duty Cleaner on the remaining surfaces.
9.
Press the whirlpool on/off button to turn on the whirlpool pump and let the pump run 
for 60 seconds.
10. Turn off the pump and allow the heavy duty cleaner/water solution to remain in the tub 
for 10 minutes. 
11. During this ten‐minute waiting time, take a long handled brush and thoroughly scrub 
all interior surfaces of the tub.
12. Open the drain to allow the heavy duty/water solution to drain from the tub. 
13. Use the shower/massage wand on the pulse setting and direct the spray into both 
whirlpool jets to back flush until the water discharging from the whirlpool inlet is clear.
14. Rinse the tub thoroughly with the shower wand on the spray setting.
15. Check the tub for damage and to ensure all surfaces of the tub are clean and that no 
visible residue remains. If residue is found, repeat STEPS 13 and 14.
Invacare Continuing Care Group
USA
One Invacare Way
Elyria, Ohio USA
44036-2125
For customer service call: 800-668-2337

SAVE THESE INSTRUCTIONS

WARNING
CAUTION
Canada
994 Hargrieve Rd.
London Ontario
N6E IP5 Canada
TUB
WATER REQUIRED
MODEL
NUMBER
2800
2001
3700
3750
3800
3600
3650
3600XL
2300
3300
4300
4300HL
5300
5300HL
6300
6300ADH
4400SS
5400SS
*NOTE: If using non‐Invacare heavy duty 
cleaner, refer to the instructions supplied with the 
cleaner to determine the proper amount required.
www.invacare-ccg.com
All rights reserved. Trademarks are identified by the symbols ™ and ®. All
trademarks are owned by or licensed to Invacare Corporation unless
otherwise noted.
Betadine is a registered trademark of Purdue Pharma L.P.
© 2008 Invacare Corporation
Part No 1154271
Rev A - 04/08
®
or
INVACARE
TO COVER JETS
HEAVY DUTY
(GALLONS)
CLEANER
REQUIRED (OZ)*
10
40
32
128
30
120
30
120
30
120
30
120
48
192
48
192
25
100
30
120
35
140
35
140
52
208
52
208
50
200
50
200
48
192
50
200

Advertisement

loading

This manual is also suitable for:

230028003300370043004300hl ... Show all