11.3 Maximum fuel charge quantity of approximately 1 hour: TABLE OF CONTENTS 11.4 Air setting with closed operation: 11.5 Adding fuel: 11.6 Operating mode in the transition period: 11 1.DESCRIPTION 11.7 De-ashing: 2. GENERAL INSTRUCTIONS, SAFETY 12. CLEANING AND CARE: INSTRUCTIONS 13.
1.Description Basic requirement: Fireplace inserts are highly suitable for the heating Ensure that the entire structure, i.e. also of living and working rooms. connecting pieces chimney, The stove body consists of a welded steel operationally safe and fireproof and can be structure.
be a minimum inflow to the heating inserts of in particular applies to the installation of bends 540 m³/h of combustion air for each m² of and deflections or long lines. firebox opening and additionally at least 1.6 m³ of combustion air per hour for other fireplaces 4.
6. Room heating capacity according to DIN 18893: In this regard, please note the details on the Equipment sheet. The values relate to rooms which do not correspond to the heat protection regulations. For rooms with a room volume in excess of 200m a heat requirement calculation according to DIN 4701 has to be carried out.
7.4 Chimney connection: connection point. Please take into account the necessary distances for primary walling, heat If the existing chimney does not have a suitable insulation, expansion joint etc. shaped connection piece for the fireplace insert a subsequent connection has to be established. The 7.5 Primary walling and heat insulation of the chimney connection height is obtained from the back and side walls:...
7.7 Permissible heat insulation and primary walling material (minimum requirements) : 8.2 Covering: Insulation materials: Insulation materials The covering of the fireplace insert on the room according working sheet 132: side must consist non-combustible 12.07.21.70.09 (=insulation material code materials of fire protection Class number).
8.5 Ornamental beams: Ornamental beams in front of the covering of the fireplace insert are permissible at a Figure: distance of at least 1 cm if the ornamental 1 = Fireplace insert beam is not part of the building and the 2 = Expansion intermediate spaces to the covering are clear joint...
10. Operation of fireplace: The fireplace inserts of Haas + Sohn with self-closing door have the designation fireplace insert EN13229-W Design 1 which means they are only suitable for operation with closed fire box and must only be operated with closed firebox.
Caution! Wood it not a slow-burning fuel so that continuous heating of the fireplace with fuel 10.2 Combustion air supply: overnight is not possible. With both the open and closed operation of the The fireplace insert is intended for the burning of fireplace carries a high demand for fresh air.
11.3 Maximum fuel charge quantity of approximately 1 hour: Fuel Quantity Total quantity Esprit Komfort 180.18, Prestige 181.18, 185.16 Exquisit 182.18 Trend 184.18, Opus 186.18 Billet wood 2 – 3 billets 2,0 kg 2,5 kg Wood 4 – 5 small pieces 1,8 kg 2,1 kg briquettes...
13.2 Warranty directives: When ordering replacement parts please state the complete type and manufacturing number of your 1. HAAS + SOHN accept guaranty for the duration chimney stove. These details can be found on the of three years calculated from the delivery to the nameplate of the device (in the wood storage end user for compartment of the device).