Wiring Diagrams - White Rodgers 1F83-0471 Installation And Operating Instructions Manual

80 series thermostat with automatic heat/cool changeover option
Table of Contents

Advertisement

WIRING DIAGRAMS

Heat Pump Connections
If you do not have a heat pump system, refer to figures 4-6.
Refer to equipment manufacturers' instructions for specific
system wiring information.
You can configure the thermostat for use with the following
heat pump systems.
Figure 3 – Heat Pump Systems
L
System
Heat Pump 1
(HP1)
Fault Indicator
or System
Malfunction
Switch
Heat Pump 2
(HP2)
Comfort Alert II Module
or Similar System
Malfunction Module
Single Stage and Multi-Stage Connections
Refer to equipment manufacturers' instructions for specific
system wiring information.
This thermostat is designed to operate a single-transformer
or two-transformer system.
You can configure the thermostat for use with the following
fossil fuel systems:
Figure 4 – Single Stage or Multi-Stage System (No Heat Pump) with Single Transformer
System
Single
Stage 1
(SS1)
Multi-
Stage 2
(MS2)
Comfort Alert II Module
or Similar System
Malfunction Module
Figure 5 – Single Stage or Multi-Stage System (No Heat Pump) with Two Transformers
L
System
Single
Energized Constantly
Stage 1
(SS1)
in Cool Mode
Fault
Indicator
(NOT
Energized Constantly
USED)
Multi-
in Heat, Off,
Stage 2
Emergency
(MS2)
Mode
NEUTRAL
120VAC
24VAC
HOT
HEATING
CLASS II
TRANSFORMER
System
Single Stage
3-wire
Zone Valve
application
Y
Y2
O/B
W/E
O
No
Energized in
Output
Cool Mode
Heat and
Emergency
Cool Mode
Mode
B
1st Stage
1st Stage
Energized in
2nd
(Compressor)
Heat, Off,
Stage
Emergency
(Com-
Mode
pressor)
L
Y
O/B
Y2
O
No
Energized Constantly
Fault
Output
in Cool Mode
Indicator
or
Cool Mode
System
1st Stage
B
Cool
Malfunction
Energized Constantly
Mode
Switch
in Heat, Off,
2nd
Emergency
Stage
Mode
Y
Y2
W2
O/B
W/E
O
No
No Output
Output
Fan Energized
Heat
Cool Mode
B
Mode
1st Stage
1st Stage
Cool
Heat Mode
Mode
2nd Stage
2nd
Stage
Figure 6 – 3-Wire (SPDT) Heat Only Zone Valve Wiring
6
W
Y
Closes
Opens
Blower/Circulator
Valve
Valve
Fan Energized
(6)
(4)
HEAT PUMP TYPE 1 (HP 1). Single stage compressor
system; gas or electric backup.
HEAT PUMP TYPE 2 (HP 2). Multi-stage compressor or two
compressor system with gas or electric backup.
After wiring, see INSTALLER CONFIGURATION section for
proper thermostat configuration.
Jumper
Jumper
W2
G
RH
RC
C
Heat Mode
Blower/
2nd Stage.
Circulator
Emergency
Fan Energized
Mode 2nd
Optional*
24 Volt
on Call for
24 Volt
Stage
24 Volt
Heat or Cool.
(Hot)
(Hot)
(Com-
Heat Mode
Set Elect/Gas
Heat
Cool
mon)
3rd Stage.
Option for
Emergency
Emergency
Mode 2nd
Mode
Stage
NEUTRAL
24VAC
HOT
SINGLE STAGE (SS 1) gas, oil or electric.
MULTI-STAGE (MS 2) gas, oil or electric.
After wiring, see INSTALLER CONFIGURATION section for
proper thermostat configuration.
Jumper
W2
G
RH
RC
W/E
Blower/
Circulator
No Output
Fan Energized
Heat
on Call for
24 Volt
24 Volt
Mode
Cool (and
(Hot)
(Hot)
1st Stage
Heat if
Heat
Cool
Heat Mode
configured
2nd Stage
for Electric
Heat)
Remove Jumper Wire
Jumper
between RH & RC
G
RH
RC
C
Blower/
Circulator
Optional
24 Volt
24 Volt
on Call for
24 Volt
(Hot)
(Hot)
Cool (and
(Com-
Heat
Cool
Heat if
mon)
configured
for Electric
Heat)
NEUTRAL
24VAC
HOT
CLASS II
TRANSFORMER
Jumper
G
RH
RC
C
24 Volt
Constant
24 Volt
(Hot)
24 Volt
(Hot)
Heat
(Com-
Cool
(5)
mon)
NOTE: If your system does
not provide an E connection,
jumper W2 to W/E to use
the Auxiliary Heat in the
Emergency Mode.
* Common connection
required for fault or
malfunction indication.
120VAC
CLASS II
TRANSFORMER
C
* Common connection
required for fault or
Optional*
malfunction indication.
24 Volt
(Com-
mon)
NEUTRAL
120VAC
24VAC
HOT
CLASS II
TRANSFORMER
NOTE: If continuous backlight or
hardwired power input are desired but
do not function in both HEAT and COOL
modes, cut the heating transformer 24V
wires and tape off. Connect the neutral
circuit disconnected from the heating
transformer to the neutral circuit of the
cooling transformer. Disconnect the wire
to the RH terminal and install a jumper
between RH and RC. Depending on
the system requirements, replace the
cooling transformer with a 75VA class II
120VAC
transformer if needed.
COOLING
NEUTRAL
120VAC
24VAC
HOT
CLASS II
TRANSFORMER
3