Zenith H19F34DT Series Service Manual page 28

Hide thumbs Also See for H19F34DT Series:
Table of Contents

Advertisement

21-F Y DL TIME AUX: Luma signal delay time adjustment
on Aux Mode. Range is 0-6. Typically set to 3.
22-F CHROMA BP-AUX:
Chroma Band Pass Filter for Aux
Mode. 0= BPF is On, 1=Take off. Typically set in 0.
23-F AUX SUBTINT: Hue adjustment on Aux Mode. Range
is 0-15. Set to 8.
24-F C KILL LEVEL: Color killer sensitivity switch. Typi-
cal value is 0.
25-F Y SW LP: Luma switch output. 0=FLAT, 1=LPF
(Fc=700 KHz).
ABCL ON/OFF switch; 0=Off; 1=ABCL On.
26-F ACL ABCL:
Typically set to 1.
27-F ABCL SNS: ABCL sensitivity low/ high switch.
0= low, 1= high. Typically set to 0.
28-F AFC1 GAIN: Horizontal AFC1 Gain switch. The range
is 0-1.
29-F AFC2 GAIN: Horizontal AFC2 Gain switch. The range
is 0-1.
30-F HVCO ADJ: Horizontal free running frequency ad-
justment. Range 0-7, typically set at 4.
31-F V SIZE: Vertical ramp amplitude adjustment. The
range is 0-254, typically set to 32.
32-F H FREE: Forced horizontal free running mode, the
range is 0-1, typically set to 0.
33-F V FREE: Forced vertical free running mode, the range
is 0-1, typically set to 0.
34-F SLICE DOWN1: Sync det. slice level section. The
range is 0-1 typically set to 0.
35-F SLICE DOWN2: Sync det. slice level switch. The range
is 0-1 typically set to 0.
36-F A-SLICE DOWN: Sync det. slice level switch during
video period. The range is 0-1 typically set to 0.
37-F FBP VTH L: Flyback pulse slice voltage. The range is
0-1, typically set to 0.
SR25-3828VD0171B
CL MODEL SERIES 39 FACTORY MENU
38-F HV BLK OFF: Horizontal and vertical blanking Off/
On RGB out switch. The range is 0-1, typically set at 0 =
On blanking output.
39-F V SYNC DET: Vertical sync det minimum width switch.
Default 1, typically set at 1.
40-F 1 WINDOW: Vertical Sync det mode. Range is 0-1,
typically set to 0.
41-F BGP FBP OFF: BGP output without FBP input. The
range is 0-1 and the default setting is 0.
42-F AIR AFT: Force to AFC in Air Band. Range is 0/1.
Typical value is 0.
43-F H PHASE: Horizontal Phase adjustment. The range
is 0-32 and the typical setting is at 9.
44-F V PHASE: Vertical Phase adjustment. The Range 0-7
is typically set to 1.
45-F SUB COLOR: For limiting the color range at mini-
mum. Range is 0-63. Typically set at 27.
46-F MAX COLOR: For limiting the color range at maxi-
mum. Range is 0-127. Typically set at 52.
47-F RF SUBTINT: Hue adjustment on RF Mode. Range is
0-15, set to 7.