Drain System - Inglis Washer User Manual

Inglis home appliances washer user manual
Hide thumbs Also See for Washer:
Table of Contents

Advertisement

Available languages

Available languages

3,
Next, loosen the two locking screws "A" and remove the two
bars "B," as illustrated below. Keep the transport
bolts,
screws, spacers and bars for future use.
The washer can be installed using the standpipe drain system
(floor or wall), the laundry tub drain system, or the floor drain
system. Select the drain hose installation method you need. See
"Tools and Parts."
Standpipe drain system - wall or floor (views A & B)
The standpipe drain requires a minimum diameter standpipe of
2" (5 cm). The minimum carry-away capacity can be no less than
4.2 gal. (15.9 L) per minute. A 2" (5 cm) diameter to 1" (2.5 cm)
diameter standpipe adapter kit is available. See "Tools and
Parts."
The top of the standpipe must be at least 23.5" (59.7 cm) high
and no higher than 72" (183 cm) from the bottom of the washer.
4.
A Screws (2)
B. Transportbars (2)
Plug the holes with the 4 clear plastic plugs and 2 black
plastic plugs, packed inside the parts bag.
\
"_)
NOTE: If the washer is to be transported
at a later date, call your
local service center.
A
23.5
= 35"
(s9.7- 88.9om)
\
B
Laundry tub drain system (view C)
The laundry tub requires a minimum carry-away capacity of
4.2 gal. (15.9 L) per minute.
The top of the laundry tub must be at least 23.5" (59.7 cm) above
the floor and no higher than 72" (183 cm) from the bottom of the
washer.
Floor drain system (view D)
The floor drain system requires a siphon break that may be
purchased separately. See "Tools and Parts."
The siphon break must be a minimum of 28" (71 cm) from the
bottom of the washer. Additional hoses might be needed.
The minimum carry-away capacity can be no less than 4.2 gal.
(15.9 L) per minute.
C
D

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents