MHSC CSDV20SNV Installation And Operating Instructions Manual

Direct vent gas stove

Advertisement

Quick Links

WARNINGS
IF THE INFORmATION IN THESE INSTRUCTIONS
ARE NOT FOLLOWED ExACTLy, A FIRE
OR ExpLOSION mAy RESULT CAUSING
pROpERTy DAmAGE, pERSONAL INjURy OR
LOSS OF LIFE.
– Do not store or use gasoline or other
flammable vapors and liquids in the vicinity
of this or any other appliance.
– WHAT TO DO IF yOU SmELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not
use any phone in your building.
• Immediately call your gas supplier from
a neighbor's phone. Follow the gas
supplier's instructions.
• If you cannot reach your gas supplier, call
the fire department.
– Installation and service must be performed
by a qualified installer, service agency or
the gas supplier.
WARNING: Improper installation, adjustment,
alteration, services or maintenance can cause
injury or property damage. Refer to this manual.
For assistance or additional information
consult a qualified installer, service agency or
the gas supplier.
This appliance is only for use with the type
of gas indicated on the rating plate. This
appliance is not convertible for use with other
gases, unless a certified kit is used.
This appliance may be installed in an aftermarket*,
permanently located, manufactured home,
where not prohibited by local codes.
*Aftermarket: Completion of sale, not for purpose of
resale, from the manufacturer.
INSTALLER: Leave this manual with the appliance.
CONSUmER: Retain this manual for future refer-
ence.
READ BEFORE INSTALLING. SAVE THESE INSTRUCTIONS
Direct Vent Gas Stove
Installation and Operating
Instructions
models:
CSDV20SNV,CSDV20DNV,CSDV20SLp,CSDV20DLp,
CSDV30SNV,CSDV30DNV,CSDV30SLp,CSDV30DLp,
CSDV40SNV,CSDV40NDV,CSDV40SLp,CSDV40DLp
D U E T O H I G H T E m p E R AT U R E S , T H E
AppLIANCE SHOULD BE LOCATED OUT OF
TRAFFIC AND AWAy FROm FURNITURE AND
DRApERIES.
CHILDREN AND ADULTS SHOULD BE ALERTED
TO THE HAZARDS OF HIGH SURFACE
TEmpERATURE AND SHOULD STAy AWAy TO
AVOID BURNS OR CLOTHING IGNITION.
yOUNG CHILDREN SHOULD BE SUpERVISED
WHEN THEy ARE IN THE SAmE ROOm AS THE
AppLIANCE.
CLOTHING OR OTHER FLAmmABLE mATERIAL
SHOULD NOT BE pLACED ON OR NEAR THE
AppLIANCE.
KEEp THE ROOm AREA CLEAR AND FREE
FROm COmBUSTIBLE mATERIALS, GASOLINE,
AND OTHER FLAmmABLE VApORS AND
LIqUIDS.
586056
CSDV cover
58D6056 8/10 Rev. 8
O N
O FF

Advertisement

Table of Contents
loading

Summary of Contents for MHSC CSDV20SNV

  • Page 1 Direct Vent Gas Stove Installation and Operating Instructions models: CSDV20SNV,CSDV20DNV,CSDV20SLp,CSDV20DLp, CSDV30SNV,CSDV30DNV,CSDV30SLp,CSDV30DLp, CSDV40SNV,CSDV40NDV,CSDV40SLp,CSDV40DLp WARNINGS IF THE INFORmATION IN THESE INSTRUCTIONS ARE NOT FOLLOWED ExACTLy, A FIRE OR ExpLOSION mAy RESULT CAUSING pROpERTy DAmAGE, pERSONAL INjURy OR LOSS OF LIFE. O FF –...
  • Page 2: Table Of Contents

    Congratulations you have purchased a state-of-the-art gas appliance featuring the Lex-Fire Burn System available exclusively on mHSC gas appliances. The Lex-Fire Burn System sets a new standard for flame appearance through innovative log design, burner technology and ember placement. Each element affecting combustion and flame appearance was carefully scrutinized and strategically balanced during the design process.
  • Page 3: Important Safety Information

    ImpORTANT SAFETy INFORmATION CSDV Series Direct Vent Gas Stove INSTALLER OWNER Please leave these instructions with the appliance. Please retain these instructions for future reference. • Read this owner’s manual carefully and completely before trying to assemble, operate, or service this fireplace. •...
  • Page 4: Code Approval

    CSDV Series Direct Vent Gas Stove ImpORTANT SAFETy INFORmATION 1. Do not use this stove to cook food or burn paper or other objects. 13. Never place anything on top of stove. 14. Do not use any solid fuels (wood, coal, paper, card- board, etc.) in this stove.
  • Page 5: Product Features

    pRODUCT FEATURES CSDV Series Direct Vent Gas Stove pRODUCT SpECIFICATIONS On/Off Switch • This appliance has been certified for use with either natural or propane gas. See appropriate data plates. • This appliance is not for use with solid fuels. •...
  • Page 6: Stove Dimensions

    STOVE DImENSIONS CSDV Series Direct Vent Gas Stove Figure 2 - Stove Dimensions Ref. CSDV20 CSDV30 CSDV40 0M\," (530 mm) 6Z\x" (673 mm) 9Z\x" (749 mm) 3Z\x" (597 mm) 8Z\x" (74 mm) 30Z\x" (775 mm) 586056 18C\v" (476 mm) 1" (533 mm) "...
  • Page 7: Stove Location

    INSTALLATION INFORmATION CSDV Series Direct Vent Gas Stove STOVE LOCATION Plan for the installation of your stove. This includes deter- • Minimum clearances to combustibles, side-wall, ceiling, mining where the unit is to be installed, the vent configura- woodwork, and windows must be maintained. Page tion to be used, framing and finishing details, and whether 9, Figure 4 any optional accessories (i.e.
  • Page 8: Clearances

    CLEARANCES CSDV Series Direct Vent Gas Stove CLEARANCES TO COmBUSTIBLES The dimensions shown in Figures 4 and 5 are minimum clearances to maintain in installing this heater. Left and right clearances are determined when facing the front of the heater. Follow these instructions carefully to ensure safe installation.
  • Page 9 CLEARANCES / HEIGHT REqUIREmENTS CSDV Series Direct Vent Gas Stove ST113 Figure 5 - Alcove Clearances ST1132 alcove clearances Alcove minimum Dimensions Height from Hearth Width Depth model CSDV0 5" (131 mm) 30" (76 mm) 36" (914 mm) CSDV30 64" (166 mm) 35"...
  • Page 10: Remove Unit From Crate

    REmOVE UNIT FROm CRATE CSDV Series Direct Vent Gas Stove 1. Remove two () straps. Figure 6 Hearth Door . Open plastic bag and slide to bottom of unit. Figure 7 3. Lift up on ash lip and pivot down to open control door. Figure 8 4.
  • Page 11: Venting Installation

    Installation of any damaged venting component. • Unauthorized modification of the venting system. • Installation of any component part not manufactured or approved by MHSC. • Installation other than permitted by these instructions. Horizontal sections of this vent system This stove must be vented to the outside.
  • Page 12: Installation Planning

    VENTING INSTALLATION CSDV Series Direct Vent Gas Stove INSTALLATION pLANNING There are two basic types of direct-vent installation: • Horizontal Termination • Vertical Termination It is important to select the proper length of vent pipe for the Never run the vent pipe level or downward. type of termination you choose.
  • Page 13: General Venting Information - Termination

    3. MHSC assumes no responsibility for the improper  only permitted if veranda, porch, deck or balcony is fully open on a performance of the appliance when the venting system minimum  sides beneath the floor: does not meet these requirements.
  • Page 14: Venting Graph

    VENTING INSTALLATION CSDV Series Direct Vent Gas Stove Termination Clearances Termination clearances for buildings with combustible and noncombustible exteriors. Inside Corner Alcove Applications* Outside Corner Combustible 6" (152 mm) Combustible 6" (152 mm) Noncombustible 2" (51 mm) Noncombustible 2" (51 mm) Balcony - Balcony - with no side wall...
  • Page 15: Installation For Horizontal Termination

    CSDV Series Direct Vent Gas Stove VENTING INSTALLATION . Rigid vent pipes and fittings have special twist-lock INSTALLATION FOR HORIZONTAL TERmI- connections. Assemble the desired combination of pipe NATION and elbows to the appliance adaptor with pipe seams 1. Determine the route your horizontal venting will take. oriented towards the wall or floor.
  • Page 16 VENTING INSTALLATION CSDV Series Direct Vent Gas Stove Vent Opening for Combustible Walls Do not recess vent termination into any 9Z\x" (41 mm) wall. This will cause a fire hazard. 9Z\x" (41 mm) 5. Slide the wall thimble over the vent pipe before con- necting the horizontal run to the vent cap.
  • Page 17 VENTING INSTALLATION CSDV Series Direct Vent Gas Stove Table 2 - Horizontal Venting maximum Vertical Vertical Vertical Horizontal (H) minimum minimum minimum CSDV20 (V) CSDV30 (V) CSDV40 (V) 4" 41Z\x" 5Z\x" 54Z\x" (610 mm) (1054 mm) (1334 mm) (1384 mm) 95Z\v"...
  • Page 18: Installation For Vertical Termination

    VENTING INSTALLATION CSDV Series Direct Vent Gas Stove NOTE: Add 1/4" rise per 1" horizontal length of pipe. Table 4 - Horizontal Venting with Three (3) 90° Figure 23 - Elbows Horizontal Termination Configuration for ST1141 maximum Rigid Venting Using Three (3) 90° Elbows Horiz term 3 elbows Horizontal Vertical minimum...
  • Page 19: Cathedral Ceiling Installation

    VENTING INSTALLATION CSDV Series Direct Vent Gas Stove Drop a plumb line from the inside of the roof to the locat- . Assemble the desired lengths of pipe and elbows nec- ing hole in the ceiling. Mark the center point where the essary to reach from the burner system flue up through vent will penetrate the roof.
  • Page 20 VENTING INSTALLATION CSDV Series Direct Vent Gas Stove VERTICAL TERmINATION CONFIGURA- Cathedral Ceiling TIONS Support Box Figures 9 through 31 show four different configurations for vertical termination. ImpORTANT: Install restrictor as indicated on chart (Figure " Minimum Below Finished 13) on Page 14. Ceiling Cut Hole 1/8"...
  • Page 21 VENTING INSTALLATION CSDV Series Direct Vent Gas Stove NOTE: Vertical (V) + Vertical (V ) = 0' (6 m) Maximum Vertical Venting (V) N O T E : I n s t a l l = 40' (1 m) restrictor into 4" Maximum collar of stove or first vent section...
  • Page 22: Stove Installation

    STOVE INSTALLATION CSDV Series Direct Vent Gas Stove CHECK GAS TypE Use proper gas type for the fireplace you are installing. If you have conflicting gas type, do not install fireplace. See dealer where you purchased the fireplace for proper fireplace according to your gas type.
  • Page 23 STOVE INSTALLATION CSDV Series Direct Vent Gas Stove A manual shutoff valve must be installed Only persons licensed to work with gas upstream of the appliance. Union tee piping may make the necessary gas and plugged 1/8" NpT pressure tapping connections to this appliance.
  • Page 24: Checking Gas Pressure

    CSDV Series Direct Vent Gas Stove CHECKING GAS pRESSURE and ELECTRICAL INSTALLATION 1. Check gas type. The gas supply must be the same as stated on the appliance’s rating decal. If the gas supply is different from the fireplace, STOp! Do not install the appliance.
  • Page 25: Electrical Installation

    ELECTRICAL INSTALLATION CSDV Series Direct Vent Gas Stove REmOTE WALL mOUNTED SWITCH A remote wall switch and up to fifteen (15) feet of 18 Ga. wire may be used with this appliance. Attach the wall switch in a junction box at the desired location on the wall. Figure 35. Do not extend beyond the wall switch wire length provided.
  • Page 26 LOG pLACEmENT CSDV Series Direct Vent Gas Stove Before you begin — This unit is supplied with ceramic fiber logs. Do not handle these logs with your bare hands. Always wear gloves to prevent skin irritation from ceramic fibers. After handling the logs, wash your hands gently with soap and water to remove any traces of fibers.
  • Page 27: Log Placement

    LOG pLACEmENT CSDV Series Direct Vent Gas Stove pLACE CSDV30 LOGS IN FIREBOx pLACE LOGS AND ROCK WOOL Figure 38 (EmBER mATERIAL) IN FIREBOx 1. Carefully remove logs from wrapping. Break up rock wool (ember material) into dime-sized . Open front door of firebox. pieces.
  • Page 28 LOG pLACEmENT CSDV Series Direct Vent Gas Stove pLACE ROCK WOOL (EmBER mATERIAL) pLACE CSDV40 LOGS IN FIREBOx IN FIREBOx Figure 40 1. Carefully remove logs from wrapping. Break up rock wool (ember material) into dime-sized . Open front door of firebox. pieces.
  • Page 29: Operating Instructions

    OpERATING INSTRUCTIONS CSDV Series Direct Vent Gas Stove FOR yOUR SAFETy READ BEFORE LIGHTING If you do not follow these instruction exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance is equipped with a pilot which must be lit by hand while following these instructions exactly.
  • Page 30: Lighting Pilot For The First Time

    OpERATING INSTRUCTIONS CSDV Series Direct Vent Gas Stove LIGHTING pILOT FOR THE FIRST TImE INITIAL LIGHTING If using a soap and water solutiong Purge air from the supply line as follows: to test for leaks, DO NOT spray • Open main shutoff valve. solution onto control body.
  • Page 31: Lighting Burner

    OpERATING INSTRUCTIONS CSDV Series Direct Vent Gas Stove LIGHTING BURNER mAIN BURNER SWITCH The “ON/OFF” switch for the main burner can be found on the back right side of the stove. This switch allows you to turn on and to turn off the main burner without using the gas valve knob.
  • Page 32: Air Shutter Adjustment (Natural Gas Only)

    AIR SHUTTER ADjUSTmENT (NATURAL GAS ONLy) CSDV Series Direct Vent Gas Stove ADjUSTING THE AIR SHUTTER The venturi of the burner is equipped with an air shutter. The opening of the venturi has been set at 1/4" for Natural Gas and fully open for Propane installation at sea level. Natural Gas Models may be adjusted for high altitude as follows: •...
  • Page 33: Cleaning And Maintenance

    CLEANING and mAINTENANCE CSDV Series Direct Vent Gas Stove Make sure the gas valve knob is in the “OFF” position. Wait at least five (5) minutes before start-ing maintenance. Allow glass to cool before cleaning. VENTING SySTEm Do not clean glass when it is hot. A qualified agency should examine the venting system Damage could occur.
  • Page 34: Glass Replacement

    5. Wrap new glass pane with tadpole gasket. Make sure you have 1/4" overlap on each side. 6. Place new glass in frame. 7. Slide glass frame back down onto stove and fasten two clamps. Figure 52 NOTE: Use only original mHSC replacement parts. Gasket Glass ST1153 Glass...
  • Page 35: Troubleshooting

    TROUBLESHOOTING CSDV Series Direct Vent Gas Stove Turn appliance OFF and allow to cool before servicing. Only a qualified service person should service and repair the heater. NOTE: All troubleshooting items are listed in order of operation. REmEDy OBSERVED pROBLEm pOSSIBLE CAUSE 1.
  • Page 36: Replacement Parts

    REpLACEmENT pARTS CSDV Series Direct Vent Gas Stove CSDV20 Replacement parts 20  586056 CSDV20 parts 58D6056...
  • Page 37 REpLACEmENT pARTS CSDV Series Direct Vent Gas Stove Ref. Description qty. CSDV20NV CSDV20pV Burner Assembly 58D050 58D050 Log Support Bracket 58D010 58D010 Pilot Assembly 37D0018 37D0019 SIT 80 Nova Valve 37D0117 37D0118 Injector 6D3006 0H3146 Venturi 45D0600 45D0600 Valve Tube 58D0163 58D0163 ON/OFF Rocker Switch...
  • Page 38: Csdv30

    REpLACEmENT pARTS CSDV Series Direct Vent Gas Stove CSDV30 Replacement parts 20  586056 CSDV30 parts 58D6056...
  • Page 39 REpLACEmENT pARTS CSDV Series Direct Vent Gas Stove Ref. Description qty. CSDV30NV CSDV30pV Burner Assembly 58D0150 58D0150 Log Support Bracket 58D004 58D004 Pilot Assembly 37D0018 37D0019 SIT 80 Nova Valve 37D0117 37D0118 Injector 58D010 0H3144 Venturi 45D0600 45D0600 Valve Tube 58D0163 58D0163 ON/OFF Rocker Switch...
  • Page 40: Csdv40

    REpLACEmENT pARTS CSDV Series Direct Vent Gas Stove CSDV40 Replacement parts 586056 CSDV40 parts 58D6056...
  • Page 41 REpLACEmENT pARTS CSDV Series Direct Vent Gas Stove Ref. Description qty. CSDV40NV CSDV40pV Burner Assembly 58D0368 58D0368 Rear Burner Assembly 58D036 58D036 Log Support Bracket 58D0310 58D0310 Pilot Assembly 0H048 0H048 SIT 80 Nova Valve 37D0117 37D0118 Front Injector 0H3150 0H3151 Rear Injector 6D3006...
  • Page 42: Massachusetts Residents Only

    CSDV Series Direct Vent Gas Stove massachusetts Residents Only — please read and follow these special requirements NOTE REGARDING VENTED pRODUCTS . Approved Carbon monoxide Detectors. Each carbon This product must be installed by a licensed plumber or gas fitter monoxide detector as required in accordance with the above when installed within the Commonwealth of Massachusetts.
  • Page 43: Warranty

    LImITED LIFETImE WARRANTy pOLICy CSDV Series Direct Vent Gas Stove MHSC warrants its products to be free of defects in material and workmanship and backs each product with a Limited Lifetime Warranty. This warranty is to the original purchaser of a MHSC product and is not transferable.