Before radio devices can be put in circulation, their agreement with European laws or
limits must be confirmed; only then may the CE symbol be applied.
The unit of measurement for the European Council's recommended limit for mobile
telephones is the "Specific Absorption Rate" (SAR). This SAR limit is 2.0 W/kg, averaged
over 10 g of body tissue. It meets the requirements of the International Commission on
Non-Ionizing Radiation Protection (ICNIRP) and was included in the European Standard
EN 50360 for mobile radio devices. The SAR regulation for mobile telephones is in line
with European Standard EN 62209-1. The maximum SAR value is calculated at the highest
output level in all frequency bands of the mobile telephone. During use, the actual SAR
level is usually much lower than the maximum value, because the mobile telephone
works in different output levels. It only transmits with as much output as is required to
reach the network. In general the following applies: The closer you are to a base station,
the lower the transmission output of your mobile telephone. The tested SAR of this
device is as follows:
Head (W/kg 10g)
1.61
NCC warning
警語
經型式認證合格之低功率射頻電機,非經許可,公司、商號或使用者均不得擅自變更頻率、加大功率
或變更原設計之特性及功能。低功率射頻電機之使用不得影響飛航安全及干擾合法通信;經發現有干
擾現象時,應立即停用,並改善至無干擾時方得繼續使用。前項合法通信,指依電信法規定作業之無
線電通信。低功率射頻電機須忍受合法通信或工業、科學及醫療用電波輻射性電機設備之干擾,減少
電磁波影響,請妥善使用。
SAR 標準值 2.0 W/kg; 送測產品實測值為 : 1.61 W/kg
For Canadian users
Operation is subject to the following two conditions: (1) this device may not
cause interference, and (2) this device must accept any interference, including
interference that may cause undesired operation of the device.
This Class B digital apparatus complies with Canadian ICES-003.
This Category II radiocommunication device complies with Industry Canada
Standard RSS-310.
Important note
IC radiation exposure statement
This EUT is compliance with SAR for general population/uncontrolled exposure
limits in IC RSS-102 and had been tested in accordance with the measurement
methods and procedures specified in IEEE 1528. This equipment should be
installed and operated with minimum distance 1.5 cm between the radiator
and your body.
This device and its antenna(s) must not be co-located or operating in
conjunction with any other antenna or transmitter.
Regulatory information
CE
Body (W/kg 10g)
1.04
NCC
Head (W/kg 10g)
1.61
Body (W/kg 10g)
N/A