PLAN DUCTWORK TOOLS AND INSTALLATION (continued) MATERIALS REQUIRED (continued) For Ductfree Installations Only: FIG. 1C One two-pack HF88 Replacement Filter Kit ROOF CAP For Installation On Kitchen Cabinets With Recessed Bottoms Only: Two 1” x 2” x 12” (approximate length) wood strips (purchase locally) Four 1-1/4”...
PREPARE HOOD FIG. 2 1. Unpack hood and check contents. You should receive: 1 - assembled hood 1 - plastic bag, containing: 4 - 7/8” wood screws for mounting hood to cabinet STEP 2 2 - 1/4” black sheet metal screws for mounting damper/ duct connector to hood 2 - aluminum filters 1 - damper/duct connector...
Page 4
PREPARE THE INSTALLATION LOCATION FIG. 4 3" NOTE IF DISTANCE BETWEEN WALL AND FRONT OF CABINET FACE FRAME IS MORE THAN 12”, THERE WILL BE A GAP BETWEEN BACK OF HOOD AND WALL. THIS IS NORMAL. TOP FRONT EDGE OF HOOD SHOULD BE 3"...
INSTALL THE DUCTWORK INSTALL HOOD 1. Position hood so that: (FIG. 8) For Ducted Installations Only: NOTE FIG. 8 THESE INSTRUCTIONS WILL FOLLOW THE PLANS MADE ON PAGE 2. START ON THE OUTSIDE AND WORK BACK TOWARD HOOD. FOLLOW APPROPRIATE DIRECTIONS FOR TYPE OF DUCT SYSTEM YOU ARE INSTALLING.
Page 6
INSTALL HOOD (Continued) INSTALL HOOD (Continued) For Ductfree Installations Only: For Ducted Installations Only: 9. Snap aluminum filter onto front of replacement filter. (FIG. FIG. 10 13) Make sure that tab on aluminum filter lines up with BLOWER DISCHARGE finger pull on replacement filter. FIG.
USE AND CARE USE AND CARE (Continued) CONTROLS (FIG. 15) HOW TO AVOID A COMMON RANGE-TOP GREASE FIRE FIG. 15 • Your range hood provides a protective barrier between the cooking surface and the cabinets. • Keep fan, filters and grease laden surfaces CLEAN according to instructions.