Mitsubishi Electric PUHZ-W85VHA2 Service Manual page 35

Air to water heat pump
Hide thumbs Also See for PUHZ-W85VHA2:
Table of Contents

Advertisement

SW2 setting
Outdoor unit setting information
ON
1
2 3 4 5 6
Plate HEX liquid pipe temperature (TH6)
– 39~88
ON
1
2 3 4 5 6
Condensing temperature (T
– 39~88
ON
1
2 3 4 5 6
Calculated maximum frequency
ON
0~150
1
2 3 4 5 6
Water inlet temperature (TH32)
0~100
ON
1
2 3 4 5 6
Ambient temperature (TH7)
-39~88
ON
1
2 3 4 5 6
Outdoor heatsink temperature (TH8)
-40~200
ON
1
2 3 4 5 6
Discharge superheat (SHd)
ON
0~255
Cooling and Heating: SHd = TH4-T
1
2 3 4 5 6
Display detail
)
63HS
63HS
35
Explanation for display
• The tens digit (Total display for applied setting)
Setting details
Display details
H·P / Cooling only
0 : H·P
Single phase / 3 phase
0 : Single phase 2 : 3 phase
• The ones digit
Setting details
Display details
Defrosting switch
0 : Normal
(Example) When heat pump, 3 phase and defrosting
(normal) are set up, "20" is displayed.
– 39~88
(When the temperature is 0: or less, "–" and
temperature are displayed by turns.)
– 39~88
(When the temperature is 0: or less, "–" and
temperature are displayed by turns.)
0~150
(When it is 100 Hz or more, hundreds digit, tens
digit and ones digit are displayed by turns.
(Example) When 105 Hz;
0.5 secs.
0~100
-39~88
(When the temperature is 0: or less, "–" and
temperature are displayed by turns.)
-40~200
(When the temperature is 0: or less, "–" and
temperature are displayed by turns.)
(When the thermistor detects 100: or more,
hundreds digit, tens digit and ones digit are
displayed by turns.)
0~255
(When the SHd is 100°C or more, hundreds
digit, tens digit and ones digit are displayed by
turns.)
1 : Cooling only
1 : For high humidity
0.5 secs. 2 secs.
1
05
Unit
Code
display
:
:
Hz
:
:
:
°C