Acer Altos 330 Series User Manual page 108

Table of Contents

Advertisement

Using a Standard Drive as C and a SCSI Drive as D
Use the Setup program to map the second standard hard disk (if one exists)
out of the configuration.
Disable Onboard SCSI Boot in Setup.
Be sure that the SCSI drive to be used as drive D is set to SCSI ID 0. Check
the drive manual for information on setting the SCSI ID for that device. You
can also use the SCSISelect utility to determine the SCSI addresses of
peripherals on the SCSI bus.
Be sure that SCSI parity checking is consistently enabled or disabled on all
devices on the SCSI bus.
Verify that the SCSI controller and the SCSI devices are properly configured
and installed.
Be sure to cycle the power OFF and ON after changing any values on a SCSI
controller, in a Setup program, or on a SCSI device. Doing this ensures that
the new initial values are loaded.
Be sure that the SCSI bus is properly terminated.
Be sure that the disk is formatted and has a partition.
Check cable connections and pin-1 orientation.
Chapter 3 - System Utilities 3-29

Advertisement

Table of Contents
loading