Detail Description Of Cycle Repair - Daewoo FRS-X22B Series Service Manual

Refrigerator
Table of Contents

Advertisement

NO.
Pinch plier and
1
connect
discharge hose
Pinch piler and
2
fix charging pipe
Discharge R-
3
600a refrigerant
Discharge
4
residual
refrigerant
5
6
1. Connect refrigerant discharge hose
to pinch plier.
2. Install the other end of discharge hose
to the outside of door.
1. Fix pinch plier to compressor charging
pipe
2. Fix tool so that there is no moving.
When there is moving, it may cause
fire by inlet of refrigerant in to a room.
1. Discharge R-600a refrigerant to outside
of a room .
[Before connect to vacuum pump]
Perform more than 7 minutes for
discharge of refrigerant
1. When it pass more than 7 minutes,
connect vacuum pump at end of discharg
Certainly operate vacuum pump at well
ventilated outside area
2. Operate vacuum pump more than 10
minutes to discharge residual refrigerant
at pipe
1. Separate welding area of del. pipe,
suction pipe, capillary tube,dryer&hot pipe
Be careful there is no damage to parts
by welding flame.
1. Change compressor, dryer
Necessarily check compressor spec.
per model and use same compressor

Hide quick links: