Interlogix NetworX NX-1700E Installation And Startup Manual
Interlogix NetworX NX-1700E Installation And Startup Manual

Interlogix NetworX NX-1700E Installation And Startup Manual

Proximity card reader

Advertisement

Quick Links

NX-1700E Proximity Card Reader
Installation and Startup
© 2012 UTC Fire & Security
All rights reserved. Printed in the United States of America.
NetworX
is a trademark of the UTC Fire & Security.
These instructions do not purport to cover all details or variations in equipment nor to provide every possible contingency to be met during installation,
operation, and maintenance. If further information is desired or if particular problems arise that are not covered sufficiently for the purchaser's
purpose, the matter should be referred to UTC Fire & Security, Gladewater, Texas, USA.
This document contains proprietary information of UTC Fire & Security, USA and is furnished to its customer solely to assist that customer in the
installation, testing, operations, and/or maintenance of the equipment described. This document shall not be reproduced in whole or in part nor shall
its contents be disclosed to any third party without the written approval of UTC Fire & Security.
Please refer to the current UTC Fire & Security product catalog for detailed warranty information.
Main
Outside the US
Main Fax
Indicates a procedure, practice, condition, or statement that, if not strictly observed, could result in personal
injury.
* This symbol indicates electrical warnings and cautions.
Warning
Indicates a procedure, practice, condition, or statement that, if not strictly observed, could result in damage to or
destruction of equipment or property.
** This symbol indicates general warnings and cautions.
Caution
Indicates an essential or important procedure, instruction, condition, or statement.
Note
Indicates a user tip. Provides helpful information that is not normally defined in regular use, but from an
experienced user.
Tip
Indicates a key or button should be pressed to enter data.
Enter
PART #
NX-1700E
Card Reader Module
NX-8E
8 – 192 Zone Control Only
NX-848E-KIT NX-8E Control, NX-148E LCD Keypad, 40VA
Transformer
NX-8
8 – 48 Zone Control Only
NX-8 Control, NX-148E LCD Keypad, 40VA
NX-848-KIT
Transformer
NX-6
6 – 12 Zone Control Only
NX-6 Control, NX-148E LCD Keypad, 40VA
NX-648-KIT
Transformer
NX-148E
Alphanumeric 48 Zone LCD Keypad
192 Zone LCD Keypad
NX-1192E
800-727-2339
903-845-6941
903-845-6811
Symbol Legend

ORDERING INFORMATION

DESCRIPTION
Technical Support
Sales & Literature
Web:
www.utcfireandsecurity.com
PART #
NX-216E
NX-320E
NX-408E 
NX-416E 
NX-448E 
NX-507E
NX-508E
NX-534E
 These units are UL listed for residential use only.
NX1700EIG05
(Supercedes NX1700EIF04)
888-437-3287
800-547-2556
DESCRIPTION
16 Zone Expander Module
Smart Power Supply and Buss Extender
8 Zone Wireless Expansion Module
16 Zone Wireless Expansion Module
48 Zone Wireless Expansion Module
Seven Relay Module
Eight Output Module
Two-Way Listen In Module

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the NetworX NX-1700E and is the answer not in the manual?

Questions and answers

Summary of Contents for Interlogix NetworX NX-1700E

  • Page 1: Ordering Information

    NX1700EIG05 (Supercedes NX1700EIF04) NX-1700E Proximity Card Reader Installation and Startup © 2012 UTC Fire & Security All rights reserved. Printed in the United States of America.  NetworX is a trademark of the UTC Fire & Security. These instructions do not purport to cover all details or variations in equipment nor to provide every possible contingency to be met during installation, operation, and maintenance.
  • Page 2: Table Of Contents

    Programming Activation Data for User Cards 1 through 120..............11 Location 284 Programming Activation Data for User Cards 121 through 240.............11 Location 285 Code Entry Logging Partition.........................11 VIII. PROGRAMMING WORKSHEETS ............................12 IX. GLOSSARY ..................................17 FCC INFORMATION ................................17 XI. UNDERWRITERS LABORATORIES INFORMATION......................17 XII. SPECIFICATIONS................................17 NX-1700E Card Reader...
  • Page 3: General Description

    GENERAL DESCRIPTION The NetworX NX-1700E is a proximity card reader / door control module used to expand the capabilities of the NetworX control panels. $ Microprocessor-controlled $ Includes one (1) low current trigger output, which can be used to control a door strike relay...
  • Page 4: Programming

            (Do not enter data.) The next segment is displayed. Each time  is pressed, the data of the next segment will be displayed for review. Shortcuts:  Previous location.  Same location.  Next sequential location. NX-1700E Card Reader...
  • Page 5: Exiting The Program Mode

    IMPORTANT NOTE Adding or de-activating user cards from a reader will cause the code for User Number 2 to become invalid. Therefore, it will need to be re-entered after all user cards are programmed into the readers. NX-1700E Card Reader...
  • Page 6: Adding One User

            Scan any card. The card information for the user entered in the previous step will be activated, and LED1 will stop flashing. After about 30 seconds, all the readers in the system will be updated. NX-1700E Card Reader...
  • Page 7: De-Activate One User

    "On" to send a Request To Exit (RTE); and activate the onboard open collector output. (Default is “On”)  Location 243, Segment 2 must be programmed with a valid zone number for the RTE to be sent. NX-1700E Card Reader...
  • Page 8: Location 241 Programming The X-10 Address For The Scan Functions

     The card reader is defaulted to the “Legacy mode”. This mode uses the same scan method as previous NX-1700E card readers. However, an alternative scan method is available by turning off LED6 in Location 242, Segment 1. Rather than passing the card (scan) within range of the card reader, the card can be held at the reader for a specified number of beeps.
  • Page 9: Location 243 Programming The Zones

    CCESS PTIONS (2 segments of binary data) Segment 1 Door Options LED1 - "On" if locking mechanism is a Maglock or Drop Bolt. LED2 - "On" if access is allowed regardless of Armed status of the system. NX-1700E Card Reader...
  • Page 10: Location 247 Programming The Opening Time For Schedule 1

    Location 258 – Days for Schedule 4 Location 270 – Days for Schedule 8 Location 259 – Opening Time for Schedule 5 Location 260 – Closing Time for Schedule 5 Location 261 – Days for Schedule 5 NX-1700E Card Reader...
  • Page 11: Location 271

    “RTE from a scanned card is to be logged as Code Entry” is enabled (Location 242, Segment 1, Option 5). Entering a 0 (zero) will send the lowest valid partition of the reader. Entering 1-16 will send the entered value as the partition. (Default is 0.) NX-1700E Card Reader...
  • Page 12: Programming Worksheets

    5 = “On” if an RTE from a scanned card is to be logged as Code Entry 6 = “On” if reader is in NX-1700E Legacy Mode 7 = “On” if an RTE from a zone or the Egress input is to be logged as Code Entry.
  • Page 13 Hour of Opening Time (24-hr format) 8 = 8 AM Seg 2 Minutes after Hour of Opening CLOSING TIME FOR SCHEDULE 2 Seg 1 Hour of Closing Time (24-hr format) 20 = 8 PM Seg 2 Minutes after Hour of Closing NX-1700E Card Reader...
  • Page 14 8 = 8 AM Seg 2 Minutes after Hour of Opening CLOSING TIME FOR SCHEDULE 6 Seg 1 Hour of Closing Time (24-hr format) 20 = 8 PM Seg 2 Minutes after Hour of Closing AYS F R SCHEDULE 6 NX-1700E Card Reader...
  • Page 15 13 = User Cards 217 – 224 User Cards 153 – 160 14 = User Cards 225 – 232 User Cards 161 – 168 15 = User Cards 233 – 240 User Cards 169 – 176 User Cards 177 – 184 NX-1700E Card Reader...
  • Page 16 DESCRIPTION DEFAULT YOUR DATA CODE ENTRY LOGGING PARTITION NX-1700E Card Reader...
  • Page 17: Glossary

    3. Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. FCC ID: CGGNX-1700E UNDERWRITERS LABORATORIES INFORMATION The NX-1700E module has received UL listing: UL294 Access Control Systems Units XII. SPECIFICATIONS DIMENSIONS Approx.
  • Page 18 Main Fax 903-845-6811 www.utcfireandsecurity.com Revision B (Mar 2012)

Table of Contents