HEATING CAPACITY - With High Efficiency Motor Furnaces (Continued)
UNIT
FURNACE MODEL
MODEL
(Y*(8,L)C/T*8V)*C20
(Y*9C/T*9V)*C16
YZF06013(C)
(Y*9C/T*9V)*C20
(Y*9C/T*9V)*D20
1. Rated CFM same as for cooling.
2. Heating MBH based on ARI standards of 70° DB entering indoor air, 72% RH outdoor air with 25 feet of interconnecting piping and no sup-
plemental electric heat operation.
3. Variable speed furnaces have B.O.D (Blower on Delay) standard.
CP equals MBH output divided by (total KW input x 3.412).
HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by the
total electric power input during the same period.
— = Not Applicable.
ACCESSORIES*
TXV Kits - 1TVM9 series thermal expansion valves precisely
meter refrigerant for optimum performance.
Bonnet Sensor (2SB13700124) - The bonnet sensor is used to
sense plenum temperature, and is optional with a gas or oil
back-up heat source. Compatible only with 13 SEER and higher
heat pumps.
Dehumidistat (2HU16700124) - Provides increased dehumidi-
fication when matched with variable speed furnace or air han-
dler.
Heat Pump Risers - (526-35389-000, 526-35390-000, 526-
35391-000) - 3", 6", or 12" risers mount easily in composite
base pan recesses, ensuring the unit stays clear of snow and
ice build-up in harsh winter weather.
Thermostats - Compatible thermostat controls are available
through accessory sourcing. For optimum performance and
installation, refer to the UPGNET "Low Voltage Wiring Diagram"
document to select and apply controls.
14
COIL
1
MODEL
STAGE
1 PH HP WITH HIGH EFFICIENCY FURNACES
FC64D
FC64D
FC64D
FC64D
SOUND POWER RATINGS*
HEATING
NET MBH
RATED
CFM
47 OD
3
1
1060
42.5
2
1630
58.0
2
1060
58.0
1
1040
42.5
2
1590
58.0
2
1040
58.0
1
1040
42.5
2
1655
58.0
2
1040
58.0
1
1085
42.5
2
1630
58.0
2
1085
58.0
UNIT MODEL
Cooling
024
71.0
030
71.2
036
71.5
042
71.4
048
71.3
060
69.8
* Rated in accordance with ARI 270-95 Standards.
Johnson Controls Unitary Products
2
COP @
HSPF
47
17 OD
3.48
38.5
9.00
3.78
39.0
9.00
3.30
3.46
38.5
9.00
3.74
39.0
9.00
3.28
3.46
39.0
9.00
3.72
39.0
9.00
3.28
3.46
38.5
9.00
3.74
39.0
9.00
3.28
(dBA)
Heating
71.5
70.8
68.1
69.8
71.5
71.8