632151-YTG-A-1010
HEATING CAPACITY - With High Efficiency Motor Furnaces (Continued)
UNIT
FURNACE MODEL
MODEL
(Y*(8,L)C/T*8V)*C20
(Y*9C/T*9V)*C16
YZF06013(C)
(Y*9C/T*9V)*C20
(Y*9C/T*9V)*D20
1. Rated CFM same as for cooling.
2. Heating MBH based on ARI standards of 70° DB entering indoor air, 72% RH outdoor air with 25 feet of interconnecting piping and no sup-
plemental electric heat operation.
3. Variable speed furnaces have B.O.D (Blower on Delay) standard.
CP equals MBH output divided by (total KW input x 3.412).
HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by the
total electric power input during the same period.
— = Not Applicable.
ACCESSORIES*
TXV Kits - 1TVM9 series thermal expansion valves precisely
meter refrigerant for optimum performance.
Bonnet Sensor (2SB13700124) - The bonnet sensor is used to
sense plenum temperature, and is optional with a gas or oil
back-up heat source. Compatible only with 13 SEER and higher
heat pumps.
Dehumidistat (2HU16700124) - Provides increased dehumidi-
fication when matched with variable speed furnace or air han-
dler.
Heat Pump Risers - (526-35389-000, 526-35390-000, 526-
35391-000) - 3", 6", or 12" risers mount easily in composite
base pan recesses, ensuring the unit stays clear of snow and
ice build-up in harsh winter weather.
Thermostats - Compatible thermostat controls are available
through accessory sourcing. For optimum performance and
installation, refer to the UPGNET "Low Voltage Wiring Diagram"
document to select and apply controls.
14
COIL
1
MODEL
STAGE
1 PH HP WITH HIGH EFFICIENCY FURNACES
FC64D
FC64D
FC64D
FC64D
SOUND POWER RATINGS*
HEATING
NET MBH
RATED
CFM
47 OD
3
1
1060
42.5
2
1630
58.0
2
1060
58.0
1
1040
42.5
2
1590
58.0
2
1040
58.0
1
1040
42.5
2
1655
58.0
2
1040
58.0
1
1085
42.5
2
1630
58.0
2
1085
58.0
UNIT MODEL
Cooling
024
71.0
030
71.2
036
71.5
042
71.4
048
71.3
060
69.8
* Rated in accordance with ARI 270-95 Standards.
Johnson Controls Unitary Products
2
COP @
HSPF
47
17 OD
–
–
3.48
38.5
9.00
3.78
39.0
9.00
3.30
–
–
3.46
38.5
9.00
3.74
39.0
9.00
3.28
–
–
3.46
39.0
9.00
3.72
39.0
9.00
3.28
–
–
3.46
38.5
9.00
3.74
39.0
9.00
3.28
(dBA)
Heating
71.5
70.8
68.1
69.8
71.5
71.8