G Series Outdoor Furnaces
FURNACE INSTALLATION GUIDE
FURNACE INSTALLATION GUIDE
Installation should be performed by a qualified installer and will comply with all
requirements of the agency having jurisdiction.
FURNACE FOUNDATION
FURNACE FOUNDATION
Find the footprint of the furnace in the Appendix of this manual
Inspect the ground conditions that you intend to install your furnace on. A cement pad
of 4-6" in thickness should be used. For outdoor installation, the furnace can also be
placed on 4 cement blocks not less than 6" wide X 10" long and 3" thick. place your
blocks so the legs will stand on the center of the blocks. Cement pads should be a little
bigger than the actual furnace, with about a 4' extra length front and back so you have
a solid working area. The furnace may be installed on a combustible floor provided a
noncombustible material such as metal or masonry liner is used in the following areas:
- Underneath the furnace
- At least 16" in front of the furnace and 8" on each side of the firebox and lower com-
bustion chamber doors.
TRENCH
TRENCH
SteelTech Inc recommends the
trench to be 24" to 36" deep and
wide enough to install your water
lines. If possible, have a gradual
slope in your trench to allow drain-
age away from your lines and out of
trench bottom. Most insulated un-
derground pipe has room for electri-
cal wire in it. If it does not, place
electrical supply in bottom of trench
and cover with 6 inches of dirt. A
minimum of R8 insulation value is
recommended and a water tight va-
por barrier such as PVC pipe or
drain tile to encase your insulation is
a must.
NOTE: If you are installing your water lines under an area where vehicles will cross,
you should increase your depth of the trench and use a schedule pipe over your lines
to reduce the pressure generated on the lines.
www.heatmasterss.com