Indoor unit installation
Mounting plate
Electrical cable
• Install the indoor unit level on a strong wall that is not subject to vibrations.
• The inlet and outlet ports should not be obstructed:the air should be able to
blow all over the room.
• Do not install the unit near a source of heat , steam,or flammable gas.
• Install the unit near an electric socket or private circuit.
• Do not install the unit where it will be exposed to direct sunlight.
• Install the unit where connection between indoor and outdoor unit is as easy
as possible.
• Install the unit where it is easy to drain the condensed water.
• Check the machine operation regularly and leave the necessary spaces as
shown in the picture.
13
Indoor Unit Installation
Condensed water drain pipe
Sleeve
Insulating covering
Water drain pipe
Before starting installation, decide on
the position of the indoor and outdoor
units, taking into account the minimum
space required around the units.
Installation of the mounting plate
1. By using a level, put the mounting
plate in a perfect square position
vertically and horizontally.
2. Drill 32 mm deep holes in the wall
to fix the plate;
3. Insert the plastic anchors into the
hole;
4. Fix the mounting plate by using the
provided tapping screws;
5. Check that the mounting plate is
correctly fixed.
Drilling a hole in the wall for the
piping
1. Decide where to drill the hole in the
wall for the piping (if necessary)
according to the position of the
mounting plate;
2. Install a flexible flange through the
hole in the wall to keep the latter
intact and clean. The hole must
slope downwards towards the
exterior. Keep the drain pipe down
towards the direction of the wall
hole, otherwise leakage may occur.
Outdoors
Indoors
5 mm
Attention
Install the indoor unit in the room to
be air conditioning, avoiding to
install in corridors or communal
areas.
Install the indoor unit at a height of
at least 2.5 m from the ground.
Indoor Unit Installation
14