Dryer Will Not Run - GE DBL333 Technical Service Manual

Large capacity dryers
Table of Contents

Advertisement

Electric Dryer
House fuse,
breaker, outlet
N
problem
Repair terminal
N
block connection.
Replace door
N
switch
Replace start
N
switch
Replace timer
N
Replace thermal
limiter and
N
correct failure
fault
Replace belt
N
switch
Replace motor
N

Dryer Will Not Run

Adequate voltage
to dryer?
Y
Connections at
terminal block
OK?
Y
Door switch
contacts closed?
Y
Start switch
contacts closed?
Y
Timer contacts
B & C closed?
Y
Contacts on
thermal limiter
closed?
Y
Belt switch
contacts closed?
Y
Check motor
centrifugal switch
reading between
contacts 4 & 5:
Or
Using a properly
grounded test
cord connected to
terminals 4 & 5
does the motor
run?
Y
Open wiring
between
components.
Locate and repair
21
Gas Dryer
House fuse,
breaker, outlet
N
problem
Replace door
N
switch
Replace start
N
switch
Replace timer
N
Replace belt
N
switch
Replace motor
N
Adequate voltage
to dryer?
Y
Door switch
contacts closed?
Y
Start switch
contacts closing?
Y
Timer contacts
B & C closed?
Y
Belt switch
contacts closed?
Y
Check motor
centrifugal switch
reading between
contacts 4 & 5:
Or
Using a properly
grounded test
cord connected to
terminals 4 & 5
does the motor
run?
Y
Open wiring
between
components.
Locate and repair.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents