Inverter

The inverter board is enclosed in a protective box
mounted on the top cover under the backsplash.
To access and remove the inverter:
1.
Remove backsplash. (See
2.
Remove the 2 Phillips-head screws that hold the
inverter box in place.
3. Lift the inverter box up. Press the 3 tabs on the
front of the inverter box and gently pry it open.
4. Mark and remove the wiring from the inverter
board. Remove the inverter.
.)
Backsplash
– 16 –
Testing the Inverter
CON2
120 VAC Input From RF Choke
The inverter receives 120 VAC through the
connector (RF choke). If 120 VAC is not present,
check the wall outlet, power cord, and RF choke.
The RF choke fi lters the line voltage and
contains an in-line fuse. It is replaced as an
assembly.
RF Choke
When the washer is plugged in, there is 5 VDC at
pins 1 and 2 on the dark blue 7-pin CON2. (See
photo.)
Testing the Inverter
Power LED
IC300
Fuse
(Continued Next Page)