Table of Contents

Advertisement

Membrane Keypanel
The membrane keypanel is attached to the
backsplash and is only available as a complete
assembly.
When ordering a replacement backsplash, the
part must be ordered as left or right, depending
upon installation.
The membrane keypanel is connected to the
control board by a ribbon cable.
Membrane Keypanel Test
To test the membrane keypanel, press the
appropriate pad and check for continuity (0 Ω)
between the following pins:
Pad
Pins
Power
1 and 3
My Cycles
1 and 4
Back
2 and 3
Help
2 and 4
Home
1 and 7
Start/Stop
1 and 5

Inverter

The inverter board is enclosed in a protective box
mounted on the top cover under the backsplash.
To access and remove the inverter:
1. Follow steps 1 and 2 under
2. Remove the 2 Phillips head screws that hold
the inverter box in place.
3. Lift the inverter box up. Press the tabs on the
4. Disconnect the wiring from the inverter board.
Testing the Inverter
.
Backsplash
– 24 –
side and gently pry it open.
Remove the inverter.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents