Exiting the Field Service Mode
FIELD SERVICE MODE
ROTATE THE CYCLE
SELECTOR KNOB TO A
LOCATION WHERE ALL
LEDs ARE LIT (88)
PRESS THE START/PAUSE
BUTTON ONCE
IDLE
Inverter/Motor Error Codes
Inverter/Motor Signal LED
•
An LED beneath the inverter cover can be viewed for diagnostic testing.
•
When motor is operating normally, and running, the LED blinks at a constant rate of 1/2-second on and
1/2-second off.
•
When motor is operating normally, and idle, the LED blinks at a constant rate of 1-second on and 1-
second off.
•
Motor/Control error condition – LED is on for .25-seconds and off for .25-seconds for a specifi ed number
of times, during a 6-second period. The 6-second cycle repeats continuously.
ROTATE THE CYCLE
SELECTOR KNOB TO ANY
LOCATION OTHER THAN
LEDs LIT (88)
PRESS AND HOLD THE
START/PAUSE BUTTON
ROTATE THE CYCLE
SELECTOR KNOB 180
DEGREES AND RELEASE
START/PAUSE BUTTON
– 38 –
LOSS OF
POWER TO
CONTROL
30 MINUTE
TIMEOUT
FROM
START OF
SERVICE
MODE
LED On