Troubleshooting - Passion Veneto Owner's Manual

Table of Contents

Advertisement

PROBLEM
Breaker trips
Circulation
pump not
running
Foamy
Water
Leak
Light doesn't
work
Low/no jet
pressure
Moved my
spa and
now it
doesn't
work
T r o u b l e s h o o t i n g
CAUSE
Wiring error
Wrong GFCI
Temperature
limit
reached
Soaps, Skin
oils, or
undissolved
sanitizer
particles
Loose
connection
Drain open
burnt out
LED
Loose wire
Loose plug
Dirty filter
Closed Jets
Closed
valves
ACV open
Low water
Wiring error
at GFCI
No power to
spa
SOLUTION
Spa Neutral wire not connected to
GFCI (connected to Neutral bus)
GFCI breaker is wrong size
This is normal. When the water
temperature is 2ºF over the set point
and warmer than 95ºF, the
circulation pump automatically turns
OFF to prevent overheating.
Close the air control valves and
allow filtration cycle to run
Add defoamer
Drain and clean spa
Clean or change filters
Rinse all bathing suits before bathing
Check and hand-tighten unions at
heater & pumps, or clamps on jets
Close drain valve or replace cap
Replace bulb
Check wiring harness to LED
Reseat L1 plug on spa pack
Air lock Bleed air from the system
Check and clean or replace filter
Open all jets by turning CCW
Open all T-handle shutoff valves on
heater and pumps
Close air control valves
Fill spa 1" above all jets
Check Neutral wiring of GFCI
Reset circuit breakers on GFCI panel
and main circuit breaker panel
18