The units in this manual contain a self-diagnostic function. If an error occurs, the STANDBY/TIMER LED will automatically begin to flash. The number
of times the LED flashes translates to a probable source of the problem. A definition of the STANDBY/TIMER LED flash indicators is listed in the
instruction manual for the user's knowledge and reference. If an error symptom cannot be reproduced, the Remote Commander can be used to review
the failure occurrence data stored in memory to reveal past problems and how often these problems occur.
Diagnostic Test Indicators
When an error occurs, the STANDBY/TIMER LED will flash a set number of times to indicate the possible cause of the problem. If there is more than
one error, the LED will identify the first of the problem areas.
Results for all of the following diagnostic items are displayed on screen. If the screen displays a "0", an error has occurred.
Diagnostic Item
STANDBY/
TIMER
flashes
Power not On
+B OCP Detection
+B OVP Detection
Vertical Deflection Stop
Video Out Abnormality
Detection
Horizontal Deflection Stop
Audio Abnormality
Detection
Note: 000 the range of values for number of operations is 000 - 255. For 256 or higher, the number remains as 255.
Display of Standby/Timer LED Flash Count
�����������
��������
������
�������
�����������
�����������������������
*������������������������������������������
Release of STANDBY/TIMER indicator blinking.
The STANDBY/TIMER indicator blinking display is released by turning OFF the power switch on the TV main unit or removing the plug from the power.

SELF-DIAGNOSTIC FUNCTION

Possible Problem Location
0
[Standby Power Supply System]
F601 open
R607 open
Q601 short circuit
[Main Power Supply System}
IC601 and R612 are broken
VDR601 short-circuit
2 times
Short circuit of power supply in each circuit
3 times
T603 pin 7 to pin 8 is open
4 times
IC 1509 (V OUT) is broken
Q1505 (V Pulse Buffer) is broken
5 times
Video Out, Q705, 732, 761, and others in C board
6 times
C515, 516 open. IC206 (YC Jungle) is broken.
8 times
IC 406 (Audio amp.) is broken.
PS401, 402 open
���������
�����
�����������������
��������������
�����������������
���������������
�������������������������
Cannot turn on the power
LED doesn't blink
Goes to the standby mode
Short circuit of the +B line
Goes to the standby mode
Raster goes to one line horizontally
A and then video signal is muted.
STANDBY/TIMER LED blinks approx.
30 secs, then blinks for the diagnosis
Raster does not appear.
The sound is not out.
Goes to the standby mode
����������������
�������
�������
�������
���������������������
����������������������
— 7 —
Self Diagnosis
Supported model
Condition
Detected Symptoms
�����������
�����������
KP-53V100
2: +B OCP 000
3: +B OVP 000
4: V Stop 000
5: AKB 000
6: H Stop 000
8: Audio 000