Command Codes Command Codes; Rs-232C Settings; Command Code System; Description Of Command Code Systems - Mitsubishi Electric DX-TL950E series Operation Manual

Digital recorder rs-232c communication capability
Hide thumbs Also See for DX-TL950E series:
Table of Contents

Advertisement

Command codes
I RS-232C settings
Communication related settings of this unit are made in "MODE" and "SETTINGS" of the <RS-232C> screen. Perform
settings so that they are the same as the connecting modem or PC.
When remote controlling this unit from a PC, set "MODE" in the <RS-232C> screen to "REMOTE A" , "RE-
MOTE B" or "REMOTE C".
"REMOTE A" : Every status information is returned from the unit.
"REMOTE B" : Status information for the command is returned from the unit.
"REMOTE C" : Status information is not returned from the unit.
Available settings on unit
Synchronization
Name on Menu
1
Transmission rate at
TRANSMISSION
the data received/
RATE
sent
2
Data bit length
DATA BIT LENGTH
3
Parity bit setting
PARITY BIT
4
Stop bit length
STOP BIT
5
Line feed setting
DELIMITER
I Command code system
2 types of command codes of "direct operation specification" and "false operation panel" can be selected according to
the purpose of the unit.
I Description of command code systems
o Direct operation specification
Control and settings are performed by checking execution, errors, etc., from the status returned from the unit for the
command sent from the PC. This command type is structured by operation setting type commands that sets operations
and menu setting type commands that directly sets various menus.
• Input format
Operation setting type commands are to be sent from the PC for each operation such as power on/off, record, playback,
etc., for the unit.
Menu setting type commands are to be specified for each menu setting of the unit.
As a general rule, do not send commands continuously, but send the next command after checking that the present
command has been executed and completed.
• Response format
After sending a command, the following items can be checked from the status returned from the unit.
1) Command execution result, error type, command name, operation status.
2) For operation setting type commands, the operation mode of the unit can be distinguished by the mode number of the
returned status.
Distinction cannot be made with menu setting type commands. (Mode number is notified only when there is change is
status.)
Example) Turn the Unit ON.
Replied status code
Command
from unit to PC
from PC
PW1
#1
RC
#2
EX,00PW1,03
When the unit cannot execute the operation setting type command or menu setting command sent from a PC,
the content is displayed in the error type of the status returned from the unit. Check the error code and take
appropriate measures.
For control type commands such as record, playback, etc., the interval between command transmission and
the actual operation (command execution) may take some time. To prevent the gap between operation and actual
execution, read the status after sending the command and check the transition of the actual execution.
Asynchronous
1200/2400/4800/
9600/19200
8 BIT/7 BIT
NONE/ODD/EVEN
1 BIT/2 BIT
CR/CR•LF
Indicates POWER ON command has been sent.
Indicates that the unit has received a command.
EX
: Indicates that a command has been executed.
#2
00
: Indicates that the execution was successful.
PW1 : Indicates response to POWER ON command.
03
: Indicates POWER ON status.
rform the fo
Pe
llowing settings on the PC
Synchronization
Name on Menu
1
X control
Not available
2
S parameter
Not available
3
CS-RS hand-shake
Available
Meaning
3

Advertisement

Table of Contents
loading