Mitsubishi Electric DX-TL950E series Operation Manual page 17

Digital recorder rs-232c communication capability
Hide thumbs Also See for DX-TL950E series:
Table of Contents

Advertisement

Command codes (continued)
• RS-232C [Direct operation specification] menu setting system command form
<TIMER PROGRAM SETTINGS> (4/4)
Commands name
Commands
ALARM SETTING A ~ D
<Menu setting>
(RECORD CAMERA)
DW,*****
for timer recording
<Inquiry for setting information>
DR,*****
ALARM SETTING A ~ D
÷
(TRIGGER)
for timer recording
<Writing of menu information>
(1)
(2)
*****
RC ≥
(3)
EX,**
DW,*****
<Reading of menu information>
(1)
RC ≥
(3)
EX,**
DR,*****
÷
Status
(1)
*****
ALARM SETTING A :
(1)
(2)
04510 ~ 04518 : ALARM 1 - RECORD CAMERA 1 ~ 9
*****
04526 ~ 04534 : ALARM 2 - RECORD CAMERA 1 ~ 9
04542 ~ 04550 : ALARM 3 - RECORD CAMERA 1 ~ 9
(1)
(2)
04558 ~ 04566 : ALARM 4 - RECORD CAMERA 1 ~ 9
*****
04574 ~ 04582 : ALARM 5 - RECORD CAMERA 1 ~ 9
04590 ~ 04598 : ALARM 6 - RECORD CAMERA 1 ~ 9
04606 ~ 04614 : ALARM 7 - RECORD CAMERA 1 ~ 9
04622 ~ 04630 : ALARM 8 - RECORD CAMERA 1 ~ 9
04638 ~ 04646 : ALARM 9 - RECORD CAMERA 1 ~ 9
04766 ~ 04774 : EMR (Emergency) - RECORD CAMERA 1 ~ 9
ALARM SETTING B :
04782 ~ 04790 : ALARM 1 - RECORD CAMERA 1 ~ 9
04798 ~ 04806 : ALARM 2 - RECORD CAMERA 1 ~ 9
04814 ~ 04822 : ALARM 3 - RECORD CAMERA 1 ~ 9
04830 ~ 04838 : ALARM 4 - RECORD CAMERA 1 ~ 9
04846 ~ 04854 : ALARM 5 - RECORD CAMERA 1 ~ 9
04862 ~ 04870 : ALARM 6 - RECORD CAMERA 1 ~ 9
04878 ~ 04886 : ALARM 7 - RECORD CAMERA 1 ~ 9
04894 ~ 04902 : ALARM 8 - RECORD CAMERA 1 ~ 9
04910 ~ 04918 : ALARM 9 - RECORD CAMERA 1 ~ 9
05038 ~ 05046 : EMR (Emergency) - RECORD CAMERA 1 ~ 9
ALARM SETTING C :
05054 ~ 05062 : ALARM 1 - RECORD CAMERA 1 ~ 9
05070 ~ 05078 : ALARM 2 - RECORD CAMERA 1 ~ 9
05086 ~ 05094 : ALARM 3 - RECORD CAMERA 1 ~ 9
05102 ~ 05110 : ALARM 4 - RECORD CAMERA 1 ~ 9
05118 ~ 05126 : ALARM 5 - RECORD CAMERA 1 ~ 9
05134 ~ 05142 : ALARM 6 - RECORD CAMERA 1 ~ 9
05150 ~ 05158 : ALARM 7 - RECORD CAMERA 1 ~ 9
05166 ~ 05174 : ALARM 8 - RECORD CAMERA 1 ~ 9
05182 ~ 05190 : ALARM 9 - RECORD CAMERA 1 ~ 9
05310 ~ 05318 : EMR (Emergency) - RECORD CAMERA 1 ~ 9
ALARM SETTING D :
05326 ~ 05334 : ALARM 1 - RECORD CAMERA 1 ~ 9
05342 ~ 05350 : ALARM 2 - RECORD CAMERA 1 ~ 9
05358 ~ 05366 : ALARM 3 - RECORD CAMERA 1 ~ 9
05374 ~ 05382 : ALARM 4 - RECORD CAMERA 1 ~ 9
05390 ~ 05398 : ALARM 5 - RECORD CAMERA 1 ~ 9
05406 ~ 05414 : ALARM 6 - RECORD CAMERA 1 ~ 9
05422 ~ 05430 : ALARM 7 - RECORD CAMERA 1 ~ 9
05438 ~ 05446 : ALARM 8 - RECORD CAMERA 1 ~ 9
05454 ~ 05462 : ALARM 9 - RECORD CAMERA 1 ~ 9
05582 ~ 05590 : EMR (Emergency) - RECORD CAMERA 1 ~ 9
(2)
*****
00000 : OFF
(3)
**
: Error type
(1)
*****
ALARM SETTING A :
05614 : ALARM 1
05616 : ALARM 3
05618 : ALARM 5
05620 : ALARM 7
05622 : ALARM 9
ALARM SETTING B :
05630 : ALARM 1
05632 : ALARM 3
05634 : ALARM 5
05636 : ALARM 7
05638 : ALARM 9
ALARM SETTING C :
05646 : ALARM 1
05648 : ALARM 3
05650 : ALARM 5
05652 : ALARM 7
05654 : ALARM 9
ALARM SETTING D :
05662 : ALARM 1
05664 : ALARM 3
05666 : ALARM 5
05668 : ALARM 7
05670 : ALARM 9
(2)
*****
00000 : MD/EXT
00002 : EXT
(3)
**
: Error type
Error type : Refer to "Command receive confirmation function".
17
Notes
:
:
00001 : ON
:
05615 : ALARM 2
05617 : ALARM 4
05619 : ALARM 6
05621 : ALARM 8
05631 : ALARM 2
05633 : ALARM 4
05635 : ALARM 6
05637 : ALARM 8
05647 : ALARM 2
05649 : ALARM 4
05651 : ALARM 6
05653 : ALARM 8
05663 : ALARM 2
05665 : ALARM 4
05667 : ALARM 6
05669 : ALARM 8
:
00001 : MD
00003 : MD&EXT

Advertisement

Table of Contents
loading

Table of Contents