Peak Level Memory; Peak Level Memory Reset - Kidde KN-COEG-3 User Manual

Carbon monoxide and explosive gas alarm
Hide thumbs Also See for KN-COEG-3:
Table of Contents

Advertisement

6. Model KN-COEG-3 Operating Characteristics
Operating and Alarm Characteristics
LED Display Shows
No display alternating
with "0" every 60
seconds.
Display shows
"GAS"
Flashing dot
"End" displayed.
Red LED flashes
every 30 seconds

Peak Level Memory

When the Peak Level button is pressed and held, the display shows the
highest CO reading taken by the CO alarm since its last reset or power
up. The Peak Level display feature will display levels between 11-999
PPM. Although the Peak Level feature will display levels below 30 PPM,
these levels will not result in an alarm no matter how long the device is
exposed to these levels. The Peak Level feature is helpful in identifying if
you have had a CO reading since resetting the alarm.
Concentrations of CO between 1 and 30 PPM can often occur in nor-
mal, everyday conditions. Concentrations of CO below 30 PPM may be
an indication of a transient condition that may appear today and never
reappear. Some CO conditions may start out as low level leaks but could
develop into CO concentrations that may become harmful.

Peak Level Memory Reset

Press the Peak Level button; with the button still pressed, press the
Test/Reset button for two seconds and release. The number on the dis-
play will turn to "0", the memory will be cleared and the alarm will
begin monitoring for CO. The Peak Level memory is also reset when the
unit loses power.
Alarm Sound Unit Status
None
1/2 second
Unit has detected gas Refer to "What to do
beep, 1/2
second silence,
repeating
None
Unit beeps every
30 seconds
Normal operation
after first 4 minutes
of 9 V battery
operation. Unit
monitoring for CO
Normal battery-only
operation– unit will
show reading only if
it senses CO or gas
End of unit life
Recommendation
Verify AC power is
restored as soon as
possible to conserve
battery.
Replace battery
When the Alarm
Sounds" for Gas
(inside front cover)
Plug into AC power
as soon possible to
conserve battery
Replace unit immedi-
ately. Unit will not
respond to CO or
Gas