AMX NetLinx Integrated Controllers NI-700/900 Hardware Reference Manual page 6

Netlinx integrated controllers
Table of Contents

Advertisement

Introduction
NI-700 Specifications
Dimensions (HWD):
Power Requirements:
Memory:
Microprocessor:
Weight:
Enclosure:
Certifications:
Front Panel Components:
Program port
Configuration DIP switch • Sets the communication parameters for the Program port.
IR RX LED
IR LED
I/O LEDs
Serial LEDs
LINK/ACT
Status
Output
Input
ID pushbutton
Rear Panel Connectors:
RS-232/422/485
(Ports 1 & 2)
2
• 1.58" x 5.54" x 5.12" (4.01 cm x 14.10 cm x 13.00 cm)
• 1 RU (rack unit) high
• 280 mA @ 12 VDC
See the NI-700 On-Board Memory Specifications section on page 4.
• 304 MIPS
• 1.30 lbs (0.59 kg)
• Metal with black matte finish
• FCC Part 15 Class B, CE, and IEC 60950
• RS-232 DB9 connector (male) can be connected to a DB9 port on a computer.
This port can be used with both Serial and NetLinx programming commands. It is
also used to both upload and download information from the NetLinx Studio 2.4
program.
• Red LED lights to when IR data is being received via the rear IR RX port.
• Red LED lights during the transmission of IR or Serial data via the rear IR port.
• Four yellow LEDs light when the rear I/O channels 1-4 are active. LED indicator
for each I/O port reflects the state of that particular port.
• Two sets of red and yellow LEDs light when the rear DB9 Ports (1 & 2) are
transmitting or receiving RS-232, 422, or 485 data:
- TX LEDs (red) light when transmitting data
- RX LEDs (yellow) light when receiving data
- LED activity reflects transmission and reception activity
• These LEDs do not reflect changes in either the RTS or CTS when hardware
handshaking is used.
• Green LED lights when the Ethernet cable is connected and an active link is
established. This LED also blinks when receiving Ethernet data packets.
• Green LED lights when the Controller is programmed and communicating
properly.
• Red LED lights when the Controller transmits data, sets channels On/Off, sends
data strings, etc.
• Yellow LED lights when the Controller receives data from button pushes, strings,
commands, channel levels, etc.
Provides the NetLinx ID (D:S) assignment for the device.
• The D notation is used to represent a device number.
• The S notation is used to represent the System number of the Master.
Refer to the NetLinx Integrated Controller WebConsole & Programming Guide for
details.
• Two RS-232/422/485 control ports using DB9 (male) connectors with
XON/XOFF (transmit On/transmit Off), CTS/RTS (clear to send/ready to send),
and 300 - 115,200 baud.
• Channel range = 1 - 255
• Channels 1 - 254 provide feedback
• Channel 255 (CTS Push channel): Reflects the state of the CTS Input if a
'CTSPSH' command was sent to the port
• Output data format for each port is selected via software
• Two DB9 connectors provide RS-232/422/485 termination
NI-700 & NI-900 Hardware Reference Guide