REAR TERMINAL SETTINGS

MODE OUT 1 ~ MODE OUT 5

The unit status can be outputted from the MODE OUT termi-
nals on the rear. There are 5 MODE OUT terminals and each
terminal can be set to generate a certain type of output.
<REAR TERMINAL SETTINGS>
>>MODE OUT 1
MODE OUT 2
MODE OUT 3
MODE OUT 4
MODE OUT 5

KEY SOUND

BUZZER

REMAIN HDD
CALL OUT SETTINGS
EMERGENCY REC DURATION
Setting ( default : "OFF" )
"REC" : Outputs signals during recording.
"PLAY" : Outputs signals during playback.
"REMAIN" : Outputs signals when the remaining HDD
device space reaches the value specified in "REMAIN
HDD".
"POWER" : Outputs signals when the power of the unit
turns on.
"MOTION1" ~ "MOTION4" : Outputs the camera num-
bers detected during motion detection recording using
binary notation (MODE OUT 1 ~ MODE OUT 4 are
linked). Furthermore, motion detection inputted the last
is maintained for 2 seconds.
Relation between a camera number and a MODE OUT output
MODE OUT terminals
1
2
O
X
1
X
O
2
O
O
3
X
X
4
O
X
5
X
O
6
O
O
7
X
X
8
O
X
9
"ALARM" : Outputs signals during alarm recording.
"LAN" : It is the MODE OUT terminal controllable from
a communication function's.
"OFF" : No signal is outputted.
Capacity warning from MODE OUT is only outputted
during recording.
1. Press the SET UP button } <SETTINGS> } <INITIAL SET
UP/INFORMATION> } Select "REAR TERMINAL SETTINGS"
screen.
2. From the 5 MODE OUT terminals, display the desired setting
for the terminal (MODE OUT 1 ~ MODE OUT 5) to output
signals and then confirm.
•••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••• Operations
OFF
OFF
OFF
OFF
OFF
ON
OFF
MAIN-10%
10M
3
4
X
X
X
X
X
X
O
X
O
X
O
X
O
X
O : Signal is outputted.
X
O
X : No signal is outputted.
X
O
3. To set other terminals, repeat step 2.
4. Turn the SHUTTLE ring counterclockwise or press the SET
UP button.
KEY SOUND
It is possible for the unit to make button sounds when
using the operation buttons on the front of the unit or
when operating the JOG dial or SHUTTLE ring.
<REAR TERMINAL SETTINGS>
MODE OUT 1
MODE OUT 2
MODE OUT 3
MODE OUT 4
MODE OUT 5
>>KEY SOUND
BUZZER
REMAIN HDD
CALL OUT SETTINGS
EMERGENCY REC DURATION
1. Press the SET UP button } <SETTINGS> } <INITIAL SET
UP/INFORMATION> } Select "KEY SOUND" in the <REAR
TERMINAL SETTINGS> screen. Display the desired setting
and confirm.
2. Turn the SHUTTLE ring counterclockwise or press the SET
UP button.
BUZZER
It is possible for a buzzer to sound when the remaining
HDD device space reaches the value set in "REMAIN
HDD" of the <REAR TERMINAL SETTINGS> screen.
Other than the above, it is possible to set the buzzer to
sound when starting alarm recording or emergency
recording, or when a warning is displayed.
<REAR TERMINAL SETTINGS>
MODE OUT 1
MODE OUT 2
MODE OUT 3
MODE OUT 4
MODE OUT 5
KEY SOUND
>>BUZZER
REMAIN HDD
CALL OUT SETTINGS
EMERGENCY REC DURATION
To sound a buzzer only when reaching a specified value :
1) Select "REMAIN" for "BUZZER" in the <REAR TER-
MINAL SETTINGS> screen.
2) Set the remaining capacity in "REMAIN HDD" of the
<REAR TERMINAL SETTINGS> screen.
To sound a buzzer when reaching the set remaining ca-
pacity or when a warning is displayed :
1) Select "WARNING" for "BUZZER" in the <REAR TER-
MINAL SETTINGS> screen.
2) Set the remaining HDD capacity (HDD MAIN RE-
MAIN/HDD SUB REMAIN) in "CALL OUT SETTINGS"
of the <REAR TERMINAL SETTINGS> screen.
OFF
OFF
OFF
OFF
OFF
ON
OFF
MAIN-10%
10M
OFF
OFF
OFF
OFF
OFF
ON
OFF
MAIN-10%
10M
49