BX Matrix Switching Systems—User Manual Before You Use the System 1、Read manual——Carefully read the manual before you use the system. 2、Installation environment——The system should be installed indoor only. Install either on a sturdy rack or desk in a well-ventilated place. 3、Lightning——Unplug the power cord during lightning or after a prolonged period of non-use to avoid damage to the equipment.
2.0 BX Matrix Host Installation………………………………………………………………...5 3.0 BX Matrix System Categories……………………………………………………....6 4.0 Matrix System Front and Rear Panels………………………………………………………6 4.0.1 BX-3044 Front and Rear Panels..................6 4.0.2 BX-3084 Front and Rear Panels………………………………………………....7 4.0.3 BX-3088 Front and Rear Panels………………………………………………....7 5.0 BX Matrix System and Perpherals Connection………………………………….………….8 5.0.1 Input/Output Ports………………………………………………………………………9...
Page 4
BX Matrix Switching Systems—User Manual 9.0 BX Matrix System Technical Parameters…………………………………………………26 10.0 Common Problems and Solutions……………………………………………………….27...
BX Matrix Switching Systems—User Manual 1.0 Matrix System Overview 1.0.1 BX Matrix System The BX Matrix switcher is a high performance switching equipment for video frequencies. It is used for multiple input/output cross switchingof video signals. It provides independent RGBHV component input/output terminals. Each RGBHV component signal is transmitted separately and switched separately, thereby minimizing signal attenuation and ensuring high definition graphics signal output.
BX Matrix Switching Systems—User Manual Power Cord BX Matrix Test and Application Software CD User Manual Green Terminal(M) Quantity BX-3044 2 Pcs BX-3084 2 Pcs BX-3088 2 Pcs 2.0 BX Matrix Host Installation The BX Series Matrix Host has a black metallic housing. It can be placed on a sturdy desk or installed on a 19-in rack.
Video Input Jack Video Output Jack RS-485 Port RS-232 Port Model √ √ BX-3044 √ √ BX-3084 √ √ BX-3088 4.0 Matrix System Front and Rear Panels 4.0.1 BX-3044 Front and Rear Panels Figure 4-1 BX-3044 Front Panel Figure 4-2 BX-3044 Rear Panel...
BX Matrix Switching Systems—User Manual 5.0.1 Input/Output ports Referring to the different models, the video signal input/output jacks are formed by the 4th row and 8th row BNC female connectors. The BX-3088 video signal input/output jack channels are numbered from left to right as NO.1 to NO.8 (in two rows). The connectors are indicated from upper to lower as R, G, B, H, and V signal terminals.
BX Matrix Switching Systems—User Manual Figure 5-4 BX Matrix and Computer Connection 5.0.3 Remote Control and Settings The BX matrix provides standard RS-232 and RS-485 serial communication ports. Aside from using the front panel keys for switching operation, you are also permitted to use the RS-232 and RS-485 serial communication ports for remote operation.
BX Matrix Switching Systems—User Manual Figure 5-6 Note: The Matrix RS-232 port is defined as DCE. 5.0.3.2 RS-485 Communication Port You can use the RS-485 port to control more than one BX product. The RS-485 Port as shown in Figure 5-7 below: Figure 5-7...
BX Matrix Switching Systems—User Manual 5.0.3.3 On/Off Switches Figure 5-8 A. DIP SW-8:RS-232/RS-485 switches ON/OFF ON:RS-232 Enables Single System or RS-485 Serial Master OFF:RS-485 Enables RS-485 Serial Slave B. DIP sw-6/7:RS-485 Terminator ON/OFF ON:Terminator ON OFF:Terminator OFF C. DIP sw 1 to 5 Setting(address setting) The ID number determines the position of a Matrix system.
BX Matrix Switching Systems—User Manual 5.0.3.4 BX Matrix System and Control System Connection A. If your PC provides RS-232,please follow connection as shown in Figure 5-9 below: Figure 5-9 NOTE: 1. RS-232 connection refer to previous Figure for operation; 2. RS-232 or RS-485 baud rates: 9600bps, no odd or even calibration address,8bit data transmission address,1bit stop address(96,N,8,1)...
Page 17
BX Matrix Switching Systems—User Manual B. If your PC provides RS-485,please follow conection as shown in Figure 5-10 below: Figure 5-10 NOTE: 1. RS-485 baud rate: 9600bps, no odd or even calibration address,8bit data transmission address,1bit stop address(96,N,8,1) ; 2. Connect your PC RS-485 port to the Matrix RS-485 port as follows: TX(+)...
BX Matrix Switching Systems—User Manual 6.0 Matrix System Control Panel Operation 6.0.1 Input/Output Switching Key Operating Mode Fast video switching of the Matrix systems can be done by pressing keys on the front panel (refer to the “Front Panel Key Pressing Instructions” for detail key pressing). Operation methods as follows: “Output Channel"+“Input Channel"...
BX Matrix Switching Systems—User Manual Part Function Key Functions The “Retrieve Key” retrieves the saved input/output corresponding relations. ---Example: First press the “RCL” key, then press the previously saved output channel key to retrieve the saved input/output status and implement this status switching. 6.0.3 Operation Examples Examle 1: Synchronously switch the NO.
Page 20
BX Matrix Switching Systems—User Manual LCD Display Operation 1. Press the NO.1 key of the output channel for 2 seconds and then enter the input channel when the red 0 on LCD begins to flicker. 2. Press the NO.4 key of the input channel for 2 seconds for selection of NO.4 channel for input and NO.1 channel for...
BX Matrix Switching Systems—User Manual LCD Display Operation 7. Press the NO.6 key of the output cahnnel for 2 seconds and then enter the input channel when the red 0 on LCD begins to flicker. 8. Press the NO.4 key of the input channel for 2 seconds for selection of the NO.4 channel for input and the NO.1, 3, 5 and 6...
BX Matrix Switching Systems—User Manual Figure 7-1 《AV Matrix》Control Software Usage Interface Scroll on the left lower corner to view contents as shown below. 7.0.2.1 Main Operation Interface Features Refer to the window menu above, the interface blue area shows crossing matrix of output ports 01-08 and input ports of 01-08.
BX Matrix Switching Systems—User Manual Second way: Step 1: First select the “Output”number keys 02, 03 and 05 to the right, and select the “Input” number key 01 to the bottom. Afterwards, press consecutively the previously selected “Output” number keys 02, 03 and 05 (or you can press the “Deselect all output” key). This way, you have selected “Input”...
BX Matrix Switching Systems—User Manual Step 2: Press the “Disconnect” key; Step 3: Press the previously-pressed output number keys 03, 05 and 06 (or press the “Deselect all output”key) to complete the operation. The final results will be as shown in Figure 8-3 below: Figure 8-3 7.0.2.3 Select all output、DeSelect all output Switching Function Usage (1)Select all output Function Description: You can use this function to select one port for input...
BX Matrix Switching Systems—User Manual 7.0.2.5 Memory Function Usage Function Description: To store and retrieve. Store Functin Description: The Store Function saves all the present input/output switching relations to any Locations from #1 to #8 you desired. A specific example of the Store Function is described below: Stores all the present input/output switching relations to Location #1.
BX Matrix Switching Systems—User Manual Figure 7-4(a) Figure 7-4(b) Function Description: Linking Methods: In “ ” select either COM1 port or COM2 port as shown in Figure 7-4 (b) ; in “ ” select 9600 for signal transmission as shown in Figure 7-4 (a) 7.0.2.8 Exit Function Applications Function Description: To exit the operating software.
Page 27
BX Matrix Switching Systems—User Manual 9.0 BX Matrix System Technical Parameters Model BX-3088 BX-3084 BX-3044 Technical Parameters Video Frequency Enhancement 250MHz (-3dB),Full Load Band Width 20nS(±1nS) Maximum Transmission Delay Switching Speed 60nS(Longest Time) RGBHV,RGBS,RGsB,RsGsBs,Composite Video Signal Type Video Input Connector...
Page 28
BX Matrix Switching Systems—User Manual Model BX-3088 BX-3084 BX-3044 Technical Parameters Storage, Operating Temp.: -40℃~+85℃ Temperature Humidity Storage, Operating Humidity:10%~90% Housing Measurements: 485(L)X286(W)X140mm(H) Product Weight 6000g 30,000 Hours Median Failure Interval Warranty 1 year warranty, lifetime protection 10.0 Common Problems and Solutions 1.
Page 29
BX Matrix Switching Systems—User Manual (3) Check if the output port number is the same as the controlled port number. (4) If none of the above circumstances happen, it could be internal failure of the product itself. You must send for repair by qualified technical engineers. 7.