ID Tech 30 User Manual page 25

Omni combined bar code and magnetic stripe reader
Table of Contents

Advertisement

EXAMPLE TWO
*AST798X*
Symbology Code 39
Desired Output: The input record must be Code 39 and be exactly
seven characters in length with the seventh character being an "X". It
is divided into three fields; the first three characters, the next three
characters, and the last character. The output should reverse the order
of the first two fields, delete the last character, and add an F1 function
code at the end of each field. In addition, a time delay of 900 millisec-
onds should be added between the fields (after the F1) and another
delay of 2000 milliseconds added to the end of the record.
Formula
ID e LEN 07 07 M 07 X C 03 C 03 A <F1>
SEND BD DLY 09 AD DLY 20
Field List
Field A AST
Field B 798
Field C X
Field D <F1>
Keystroke Sequence
Prior to data editing, enable function codes in general selection
Enter Data Editing Setup
Enter Data Editing and Enable
Enter Code ID and e (for Code 39) JC<ENTER>e<ENTER>
EnterLengthand 0707
Enter Match and 07X
Enter Count and 03
Enter Count and 03
Enter Add Field & <F1> character JJ<ENTER>\F1<ENTER>
Enter Field Sequence and BD
Enter Add Delay and 09
Enter B and C characters
Enter Add Delay and 20
Enter Exit Setup
Output Data
798<<F1>>.9s delay AST<<F1>>2s delay
4 4
/E/D/FJ<ENTER>
JA<ENTER>1<ENTER>
JD<ENTER>0<ENTER>7<ENTER>0<
ENTER >7<ENTER>
JE<ENTER>0<ENTER>7<ENTER>X
<ENTER
JF<ENTER>0<ENTER>3<ENTER>
JF<ENTER>0<ENTER>3<ENTER>
JK<ENTER>B<ENTER>D<ENTER>
JM<ENTER>0<ENTER>9<ENTER>
BC<ENTER>
JM<ENTER>2<ENTER>0<ENTER>
JZ<ENTER>
EXAMPLE THREE
Track
MSR Track 1 data
Desired Output: Divide it up into seven fields so that the 1st field is the
first two characters, 2nd field is all characters from the first field to the
first "^" character, 3rd field is the first "^" character, 4th field is the
data between "^" marks, 5th field is the next "^" character, 6th field is
the next four characters, 7th field is the remaining characters. In
addition, an <ENTER> is inserted between fields in the data output
record. Only the 4th, 2nd, and 6th fields are outputted.
Formula
ID k C 02 S ^ S ^ C04 A<ENTER> SEND
DHBHFH
Field List
Field A
Field B
Field C
Field D
Field E
Field F
Field G
Field H
Keystroke Sequence
Enter Data Editing Setup
Enter Data Editing and Enable
Enter Code ID and k (for MSR Track 1)
Enter Count and 02
Enter Search String and the ^ character
Enter Search String and the ^ character
Enter Count and 04
Enter Add Field & the <ENTER> character JJ<ENTER> ^N<ENTER>
Enter Field Sequence and DHBHFH
Enter Exit Setup
Output Data
FISH/MARY<ENTER>0123774965
<ENTER>9612<ENTER>
%B
0123774965
^
FISH/MARY
^
9612
4379F?
<ENTER>
/D/FJ<ENTER>
JA<ENTER> 1<ENTER>
JC<ENTER> k<ENTER>
JF<ENTER> 0<ENTER>
2<ENTER>
JG<ENTER> ^<ENTER>
JG<ENTER> ^<ENTER>
JF<ENTER> 0<ENTER>
4<ENTER>
JK<ENTER> D<ENTER>
H<ENTER> B<ENTER>
H<ENTER> F<ENTER>
H<ENTER>
JZ<ENTER>
4 5

Advertisement

Table of Contents
loading

This manual is also suitable for:

2550607080

Table of Contents