6. Remove the four 3/16-in. Allen-head shoulder
bolts (2 on each side) that attach the mullion to
the freezer walls.
7. Pull out the mullion from the recesses (1 on
each side) in the freezer walls.
8. Disconnect the mullion wire harness.
Note: To test the operation of the mullion heater,
disconnect the humidity sensor. Within the next 20
minutes (duty cycle), the control will recognize the
open humidity sensor, the heater will then receive
voltage, and the mullion will get warm.
Fresh Food/Freezer Mullion Heater
The fresh food/freezer mullion heater is foamed in
place and is located behind the cabinet fl ange and
between the freezer and fresh food compartments.
Note: If the Energy Saver light (if available) is
on, then the fresh food/freezer mullion heater is
disabled.
The heater is not replaceable.
The EMI Filter is accessed from the back of the
refrigerator and is located on the left side of the
compressor.
To remove the EMI fi lter:
1. Remove the 5/16-in. hex-head screw that
2. Pull the bracket out and remove the 1/2-in. nut.
3. Cut the 2 plastic wire ties that hold the EMI fi lter
Wire
4. Mark and disconnect the wires from the EMI
Harness
– 54 –
EMI Filter
attaches the bracket to the cabinet.
5/16-in.Screw
1/2-in. Nut
to the bracket.
fi lter.
Wire Tie
Wire Tie