GE Profile PGCS1RKZ Technical Service Manual page 37

Profile bottom mount ice and water refrigerators
Hide thumbs Also See for Profile PGCS1RKZ:
Table of Contents

Advertisement

2. Carefully lower the interface and disconnect the
3 wire harnesses.
Wire Harnesses
3. Remove the 4 Phillips-head screws and the
dispenser housing from the dispenser recess.
The dispenser cradle switch is attached to the left
side of the dispenser housing with a Phillips-head
screw.
Each of the 2 dispenser LED boards are attached to
the dispenser housing with a plastic clinch rivet.
Switch
LED Board
The duct door heater consists of the heater, door,
and door seal, available as an assembly. The heater
operates on 13.6 VDC and has an approximate
resistance value of 109 . The assembly is
connected with a single wire harness and can be
unsnapped from the solenoid-operated door crank.
The duct door heater is in a parallel circuit with the
recess heater and the door gasket heater. These
heaters operate based on temperature settings.
example, a freezer setting of mid-range temperature
or higher equals 100 percent on-time except during
ice dispense. Applied voltage to this circuit can be
tested at dispenser board J4-2 to J4-6.
The solenoid operates on 13.6 VDC and has an
approximate resistance value of 13 . The solenoid
is connected with a single wire harness and is
attached to the recess with 3 Phillips-head screws.
Applied voltage to solenoid can be tested at
dispenser board J1-1 to J1-2.
RECESS HEATER
DOOR GASKET HEATER
DUCT DOOR HEATER
Duct Door Heater
Rivet
– 37 –
DUCT DOOR SOLENOID
R=145
R=62
DISPENSER BOARD
R=109
J4-6
J4-2
RED
RED
RED
Door Crank
(Continued next page)
For
13.6 V RED
Solenoid

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Profile pfss5rkzProfile pfcf1rkzProfile pgss5rkz